ENGLISH ENGLISH
Drawing A
INSTALLATION DIMENSIONS
b
a
z
d
80
892
Fig. A
Fig. B
Table A: Recommended dimensions
Opening a b c (*) d (**)
angle "
αα
αα
α" (mm) (mm) (mm) (mm)
90° 145 145 290 100
110° 125 125 290 80
(*) working excursion of piston rod (**)maximum dimensions
CALCULATING INSTALLATION DIMENSIONS:
GENERAL RULES
If modifications to the dimensions specified in Table A
are necessary, proceed as follows:
- For 90° leaf opening: a + b = c
- For leaf opening over 90°: a + b < c
- The lower the dimensions of a and b the higher the gate
speed. Always respect current standards.
- Limit the difference between a and b to within 4 cm: larger
differences alter speed considerably during opening and
closing.
- For reasons of operator clearance, the minimum value for
Z is 45 mm (fig. A)
If the dimensions of the gate post or position of the hinge do
not allow for the specified distance of “a”, make a recess
in the gate post as shown in fig. B.
300 mm
150 mm
100 mm
412 AUTOMATION SYSTEM
These instructions apply to the following models:
Operators 412 and 412-24V
The FAAC 412 AUTOMATION SYSTEM for swing gates comprises
two electromechanical operators which drive the gate leaves
by means of a worm screw.
The system locks mechanically; therefore no electric lock is
required.
ÜÜ
ÜÜ
ÜTo obtain anti-crushing protection, you have to use elec-
tronic control units with a torque control electronic device.
The 412 automation was designed and manufactured to con-
trol access of vehicles.
Avoid any other use whatever.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
Table 1:
412 operator technical specifications
412 412-24V
Power supply 230 V~ 50 Hz 24Vdc
Absorbed power (W) 280 70
Current drawn (A) 1,5 3
Electric motor 1400 rpm
Motor winding thermal cutout 140 °C /
Capacitor 8 µF/400V /
Max. thrust/traction force (daN) 350 250
Rod stroke (mm) 290
Rod speed (cm/s) 1,6
Temperature range (°C) -20 Ö +55 °C
Operator weight (Kg) 6,5
Housing protection IP 44
Duty cycle (cycles/hour ) 18 50
Maximum leaf length (m) 1,80
Fig. 1
162
5
7
3
4
Motor Unit
Power cable
Worm screw
Front bracket
Rear bracket
Cable cover
Cover
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 412 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 412 in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info