Room temperature reaches the set value (SET temperature)
When the set room temperature value is reached, the stove heat output is automatically set to the minimum value. During this phase, “MODULAT-” appears on
the display. If room temperature falls below the set value (Set temperature), the stove will return to “WORK” mode and to the previously set heat output (Set heat
output). If there is an external thermostat and the room temperature has been set to T-e, if the thermostat is open it will begin modulation and if closed, it will return
to the heat output set.
Stand-by
When enabled in the menu, the Stand-by function allows the stove to be switched off after complying with the following conditions. It is enabled if, for a certain
time, the room temperature is higher than the set temperature (Room set) plus a pre-set temperature delta. “OK STBY” appears on the display. At the end of the
set time, the message “COOLING WAIT” appears on the display. In this state, the stove has an auger tube closed (auger tube off) and the heat exchanger switches
off. When the fume temperature reaches a given threshold, the stove enters stand-by mode and the wording “STAND-BY” scrolls across the display. The auger,
heat exchanger and exhaust blower are all switched off.
The stove restarts if the room temperature falls below the set temperature (Room set) minus the threshold given by the temperature delta.
Stove switch off
Hold P3 button down to switch off the stove. The message “FINAL CLEANING” appears on the display. The auger tube motor stops (the auger tube LED is off)
and the exhaust blower speed is pre-set. The fan of the exchanger (exchanger LED on) remains active until the fume temperature falls below a pre-set value.
After a certain time, if the fume temperature is below a given threshold, the stove switches off and the message “OFF” is displayed.
05 ALARMS
In the event that an operating fault occurs, the board intervenes and signals the occurrence of an irregularity, switching on the alarm LED (alarm LED on) and
emitting acoustic signals.
The possible alarm messages are listed below:
Display showsNo. Cause
BLACK OUT (1)Absence of mains voltage
SMOKES TEMP.(2)Fume overheating
REG. ENCODER(3)Check fume motor encoder
NO ENCODER(4)Exhaust blower fault, not working
FAILED IGNITION(5)Stove does not ignite
CHECK PELLET(6)Shutting down due to insufficient pellets
DRAW INSUFF- (11) Burn pot or air extraction pipe obstructed
CLEANER FAILURE (12) Burn pot cleaner is blocked/Firebox door not shut correctly
AUGER ENCODER (13)The board does not read the auger tube encoder. No connection
AUGER TRIAC (14) The auger tube turns continuously
In case of alarm, the stove is immediately switched off.
Alarm status is reached after a given time, EXCEPT BLACK-OUT ALARM, and can be reset by prolonged pressure on button P3. Every time an alarm is cleared,
for safety, a stove shutdown phase is started. The alarm LED (alarm LED on) will remain on and the buzzer, if enabled, will sound intermittently during the entire
alarm phase. Should the alarm not be cleared, the stove will in any case be switched off and the alarm message will remain on the display.
Safety thermostat
If the general safety thermostat detects a water temperature exceeding the trigger threshold, it immediately
switches off the auger tube (to which it is connected in series), while the controller acquires this change in status.
The THERMIC SEC. message is displayed and the system is shut down. Unscrew the black cap on the back of
the stove and press the button to reset the contact.
Negative pressure alarm
This alarm occurs if:
•The flue pipe is non-compliant: the pipe must keep the minimum pressure in Pascals as required by the manufacturer (see TECHNICAL DATA) at both
minimum and maximum heat output.
•The flue pipe or combustion air intake is obstructed.
•The combustion chamber door and/or pallet hopper door are open.
•Excessive dirt inside fume circulation area: empty the ash that is deposited in the part adjacent to the ash drawer compartment.
Black-out Alarm
If a power failure occurs for a certain period of time, the device will go into a BLACK-OUT alarm when the power comes back on.
It is necessary to wait for the stove to cool down and then turn it back on.
SERVICE MESSAGE
The stove will display the message SERVICE (or SER) during operation depending on the number of hours of operation. The wording does not lock operation of
the stove, but non-routine maintenance will be required by an authorised technician, who will reset the service hours.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor TREVISI at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor TREVISI in the language / languages: English as an attachment in your email.
The manual is 3.64 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.