It is used to enable/disable and to set the chronothermostat functions on weekends (days 6 and 7, i.e. Saturday and Sunday). To enable, press the P1 and
P2 buttons. Setting the times Start 1 and Stop 1 sets the operating period for Saturday, while Start 2 and Stop 2 are used to set the stove operation for
Sunday.
DATE AND TIME
Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the time clock 3/5 year-long autonomy. Set the
current date by pressing OK and the respective arrows to increase or decrease the selected values.
LANGUAGE
Use this command to select one of the languages available. To move to the next language press P1 (increase) to go back, press P2 (decrease) and to confirm
press P4.
SETTINGS
This menu includes:
BUZZER MODE: this is the buzzer on the board. This sub-menu can be used to activate or deactivate the buzzer
RETROILLUMINAZIONE ON: duration of remote control lighting
POWER ON: time the display stays on
LUMINOSITA’: on or off
CONTRASTO: display contrast adjustment
TONI TASTI: activation/deactivation of the remote control key beep
INITIAL LOAD
This function is only available when the stove is OFF and is used to load the auger when the stove is started for the first time when the pellet hopper is empty. After
selecting the menu, press P1. The exhaust blower switches on at the maximum speed and the auger tube (auger tube LED on) starts working. They will switch off
once the period of time indicated on the display has elapsed or after pressing the P3 button.
STATE STOVE
Enter the STOVE STATUS menu, after pressing the P4 button, the display scrolls the status of a number of variables during operation of the stove at work.
USER SETTINGS
This menu permits the pellet drop due to pellet change by a preset percentage to be increased or decreased.
TECHNICAL MENU
This menu item is reserved for the stove installer.
STAND-BY
In this menu it is possible to activate or deactivate the automatic stand-by of the stove. When selected, if the room temperature exceeds the set temperature by
2°C, the stove will automatically switch off and then switch on again when the room temperature drops below 2°C with respect to the set temperature.
04. USER FUNCTIONS
Standard functioning of a control board properly installed on an air stove is described below with reference to the functions available to users.
Stove ignition
Hold P3 button down for a few seconds to switch on the stove. Ignition is signalled on the display with the wording “CHECK UP”. In these conditions the stove is in
the pre-heating state, the burn pot is cleaned, the glow plug (visible with the glow plug LED) and the fume extraction fan come on.
Any problem detected during the switching-on phase is indicated on the display and the stove goes into alarm status.
Loading with Pellets
After approximately 1 minute, the pellet loading phase begins and the message “LOAD PELLET” appears on the display. During the initial phase, the auger tube
loads the pellets into the burn pot for a fixed amount of time. In the second phase the auger tube turns off, while the speed of the fumes and the glow plug remain
in the previous state. If ignition does not occur after this phase, the auger tube is switched on again and the glow plug remains on.
Fire present
After the temperature of the fumes has reached and exceeded a preset threshold, the system switches to ignition mode and “STABILIZZAZIONE” appears on the
display.
The speed of the fumes is fixed, the auger tube turns on for a fixed time and the glow plug is turned off. Any problem during this phase will cause the control board
to stop and the stove to go into error state.
Stove operational
After the temperature of the fumes has reached and exceeded a given value and has maintained it for at least a predetermined time, the stove goes into work
mode which is the normal working mode. The upper display shows the time and the room temperature and the lower one the set power and the power in which
the stove is found. The heat output can be set by pressing the P2 key and the room temperature can be set by pressing the P1 button. If the fume temperature
reaches a certain set threshold, the air exchanger fan turns on. Room ventilation can be excluded from the BLOWER MODE menu.
After this phase, the stove cleans the burn pot. “Burn pot cleaning” scrolls on the display, the auger is switched on (auger LED on) and the exhaust blower is
switched on. Once the set period of time has elapsed, the stove goes back to the working mode.
Changing set heat output
During normal stove operation (WORK), the heat output can be changed using the P2 button. Press the P2 button again to increase the heat output and the P1
button to decrease it. The display will show the set heat output. To exit the set, wait 5 seconds without performing keyboard operations, or press P3 or P4.
Changing set room temperature
Press P1 button to change the set room temperature. The display shows the set room temperature (SET temperature value). Press P1 (increase) and P2
(decrease) buttons to modify the temperature. The value is saved after approx. 5 seconds and the display goes back to normal. Otherwise, press P3 or P4 to exit.
External thermostat/chrono-thermostat use
If you want to use an external programmable thermostat, connect it to the TERM clamps (connector CN7 pin 7-8).
•External thermostat
•External chrono-thermostat
The stove external thermostat is enabled when the contact is closed with stove on.
Changing the ducting ventilation (TREVISI only)
To change the ducting speed, press button P5 and adjust the ventilation speed. The setting goes from 0 to 5 and Automatic. By setting the speed to 1,2,3,4,or 5
the ducting will always operate at the same speed even when the stove heat output is changed. By setting to Automatic, the ducting will operate according to the
heat output of the stove. Setting to 0 deactivates ducting. Everything else stays the same except for the wording in red.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor TREVISI at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor TREVISI in the language / languages: English as an attachment in your email.
The manual is 3.64 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.