Once fume temperature has reached and exceeded Pr13 parameter value, the stove goes into the switching on mode (ACC). In this phase temperature stabilises
for a period of time set by Pr02 parameter. In case the contrary is arrested and the error message (ALAR).
Stove operational
Once fume temperature has reached and exceeded Pr13 parameter value, maintaining it for the period of time set by Pr02 parameter, the stove enters the normal
working mode. The upper display shows the heat output set by means of P5 and P6 buttons, while lower display shows room temperature.
Changing set heat output
During the normal operating mode (stove running) the user can change the heating capacity by means of the buttons P6 (increase) and P5 (decrease). The set
heating capacity is displayed on the top screen.
Changing set room temperature
Press SET button (P3) to change room temperature and visualise the set room temperature (SET TEMP). Press P1 and P2 buttons to increase or decrease,
respectively, the temperature value.
The new value is saved after approx. 3 seconds and the display goes back to normal.
Press P3 button (SET) to visualise the set room temperature (SET TEMP).
It will remain on the display for about 2 seconds.
When the set room temperature value is reached, the stove heat output is automatically set to the minimum value. ECO (Economy) message appears on the
upper display and the room thermostat LED switches on.
Stove switch off
Hold down P4 button for approx. 2 seconds to switch off the stove. “OFF” appears on the upper display, while the lower display shows current time.
The Auger tube motor stops and the exhaust blower speed increases. The exchanger blower remains on until the fume temperature reaches a value below the
preset Pr15 value. The exhaust blower switches off after approx. 10 minutes. Depending on the version, it may be necessary to wait the period of time set by Pr73
parameter before switching on the stove again. During the wait, P4 button is inactive and the following message appears asking users to wait until the end of the
switching off phase (COOL FIRE).
The same happens whenever the fume temperature exceeds the maximum value set by Pr14 parameter.
Once the temperature falls again within the set range, the stove goes back to the normal working mode.
Burn pot cleaning
When the stove is in the working mode, the (STOP FIRE) mode is activated for the period set by Pr12 parameter at the intervals set by Pr03 parameter.
Programmable thermostat
The programmable thermostat function allows for the programming of the stove automatic switching on and off during the week.
Press P3 button twice to enter the programming mode. Press P3 button again to cycle through all the parameters available. Press instead P4 button to exit the
programming at any time. The programmable thermostat parameters are listed below:
Parameter Description Available values
UT01 Current day setting and programmable thermostat enabling/disabling DAY1,….DAY7; OFF;
UT02 Current time setting From 00 to 11 pm
UT03 Current time minute setting From 00 to 60
UT04 ONLY FOR TECHNICIANS – DO NOT enter any setting
UT05 PROGRAMME 1 switching-on time setting From 00:00 to 11:50 pm by 10ʼ steps
UT06 PROGRAMME 1 switching-off time setting From 00:00 to 11:50 pm by 10ʼ steps
UT07 Day selection with stove switching on according to PROGRAMME 1 ON/OFF for days from 1 to 7
UT08 PROGRAMME 2 switching-on time setting From 00:00 to 11:50 pm by 10ʼ steps
UT09 PROGRAMME 2 switching-off time setting From 00:00 to 11:50 pm by 10ʼ steps
UT10 Day selection with stove switching on according to PROGRAMME 2 ON/OFF for days from 1 to 7
UT11 PROGRAMME 3 switching-on time setting From 00:00 to 11:50 pm by 10ʼ steps
UT12 PROGRAMME 3 switching-off time setting From 00:00 to 11:50 pm by 10ʼ steps
UT13 Day selection with stove switching on according to PROGRAMME 3 ON/OFF for days from 1 to 7
UT14 PROGRAMME 4 switching-on time setting From 00:00 to 11:50 pm by 10ʼ steps
UT15 PROGRAMME 4 switching-off time setting From 00:00 to 11:50 pm by 10ʼ steps
UT16 Day selection with stove switching on according to PROGRAMME 4 ON/OFF for days from 1 to 7
Press P1 and P2 buttons to enable the programmable thermostat. Then set the current week day. (DAY 7 = Sunday).
Press P1 and P2 buttons and then select OFF to disable the programmable thermostat.
PROGRAMME 1 SWITCHING ON/OFF (example morning)
UT05 –UT06
Set the PROGRAMME 1 stove switching on and off times by modifying these two parameters. Their setting is active if the UT01 parameter is set to mode.
UT07
Set the days when PROGRAMME 1 (ON) is active and the days when IT IS NOT (OFF) by modifying UT07. This parameter is active when UT01 is set to the
current day.
Press P2 button to select the day of the week and then enable (ON)/disable (OFF) stove switching on/off according to PROGRAMME 1 by means of P1 button.
In the example below, the stove switches on only on Saturdays and Sundays according to PROGRAMME 1 (morning).
Set the PROGRAMME 2 stove switching on and off times by modifying these two parameters. Their value can be set if UT01 parameter is set to the daily or
weekly mode.
UT010
Set the days when PROGRAMME 2 (ON) is active and the days when IT IS NOT (OFF) by modifying UT10. This parameter is active when UT01 is set to the
current day.
Press P2 button to select the day of the week and then enable (ON)/disable (OFF) stove switching on/off according to PROGRAMME 2 (afternoon) by means of
P1 button. In the example below, the stove switches on in the afternoon only on working days.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Eva Calor Erika at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Eva Calor Erika in the language / languages: English as an attachment in your email.
The manual is 5,83 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.