814105
17
Zoom out
Zoom in
Previous page
1/27
Next page
Summary digram of OPERATING MODES
SETTABLE
POWER
SETTABLE
ACCUMULATION
CHOSEN
SETTABLE
AMBIENT
TEMPERATURE
VENTILATION
SET (ON/OFF) STAND-BY CONDITIONS FOR
STAND BY
PWR
(POWER) NO YES NO NO Always active
Accumulation
satisfied
CLAS
(CLASSIC) YES NO YES YES Settable
Ambient
temperature
satisfied
HYBR
(HYBRID) NO YES YES NO Settable
Accumulation and
ambient
temperature
satisfied
Changing set heat output
During stove normal operation (WORK), the heat output can be changed by using the P2 button. Press the P2 button again to increase the heat output and the
P1 button to decrease it. The display will show the set heat output. To exit the set, wait 5 seconds without performing keyboard operations, or press P3 or P4.
Changing set room temperature
Press P1 button to change the set room temperature. The display shows the set room temperature (SET temperature value). Press P1 and P2 buttons to increase
or decrease, respectively, the temperature value. The value is saved after approx. 5 seconds and the display goes back to normal. Otherwise, press P3 or P4 to
exit.
The room temperature / storage temperature reaches the set temperature (SET temperature)
When the room and storage temperature have reached the set value, the heat output of the stove is automatically brought to the minimum value. During this
phase the display shows the message "MODULAT-". If room temperature falls below the set value (Set temperature value), the stove will go back to the "Work"
mode and to the previously set heat output (Set heat output). If there is an external thermostat and the room temperature has been set to T-e, if the thermostat is
open it will begin modulation and if closed, it will return to the heat output set.
Stand-by
When enabled in the menu, the Stand-by function allows the stove to be switched off after complying with the following conditions. It is enabled if, for a certain
time, the room temperature is higher than the set temperature (Room set) plus a pre-set temperature delta. The display will show the wording “OK-STDBY”. At
the end of the given time, the message "WAIT COOLING" appears on the display. In this state, the stove has an auger tube closed (auger tube off) and the heat
exchanger switches off. When the flue gas temperature reaches a given threshold, the stove enters stand-by mode and scrolls the message "HOLD REQUEST.
The auger (auger LED off), exchanger and the fumes fan are off.
The stove switches on again if the room temperature drops below the set temperature minus the threshold given by the temperature delta.
Stove switch off
Hold P3 button down to switch off the stove. The message "SWITCH OFF" appears on the display. The auger tube motor stops (the auger tube LED is off) and
the exhaust blower speed is pre-set. The fan of the exchanger (exchanger LED on) remains active until the fume temperature falls below a pre-set value. After a
certain time, if the temperature of the fumes is below a given threshold, the stove switches off, displaying the message “OFF”.
15
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Costanza at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Costanza in the language / languages: English as an attachment in your email.

The manual is 3.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Costanza

Eva Calor Costanza User Manual - German - 27 pages

Eva Calor Costanza User Manual - French - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info