07.2 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance. Avoid installations with electric cables
that run close to fume pipes or hot components that are suitably insulated. The voltage is 230V while the frequency is 50Hz.
The electrical system, at the connection point, must include an earth connection as required by EEC Regulation 73/23 and EEC 93/98.
07.3 EXTERNAL THERMOSTAT
In this product it is possible to install an external thermostat. This operation may only be performed by authorised personnel. Use a 2-pole cable with everyday
double insulation. Connect the two poles to the connector of the electronic board to the TERM connector. Enable the external thermostat by bringing the room
temperature with the P2 key up to 7°C. In the event that the thermostat is closed, the appliance works at the set power. If the thermostat is activated, the appliance
will work in the MODULAT- state until it is switched off; if it is on STAND-BY, it is activated.
07.4 IGNITION
The first procedure to be carried out is to connect the plug of the product to the mains; fill the pellet hopper (pay special care not to empty the entire bag at once,
but to carry out the procedure slowly so as not to introduce any pellet powder present in the bag into the hopper). If applicable, be careful not to damage the pellet
hopper door gasket and keep the support surface of the hopper clean.
Do not use pellets of poor quality. The use of substandard pellets can prevent the stove from reaching its maximum yield due to poor combustion and degradation
of the stove itself. Check that the door of the pellet hopper is fully and correctly closed otherwise the stove will not work properly. Load the pellets then from the
main menu perform the INITIAL LOAD, and then turn on the stove.
08. PRODUCT USE
08.1 REMOTE CONTROL
Proper functioning and control adjustment devices
Console
The remote control shows the information concerning the stove operating status. A variety of data can be displayed and settings carried out according to the level
of access by using the menu. Depending on the selected mode and on their position on the display, the data visualised may acquire different meanings.
PANEL DESCRIPTION
Button P1 Increase:
When in programming mode, use this button to modify/increase the selected menu value. When in working/switched off mode, instead use this button to increase
the room thermostat temperature value or stove heat output.
Button P2 Decrease:
The button in programming mode modifies / decreases the selected menu value, in working / off mode it decreases the value of the room thermostat temperature
or stove heat output or the storage temperature.
Button P3 ON/OFF release:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status (switched on or off).
By simply pressing, the remote control display comes on. Should any alarm have blocked the stove, press this button to unlock it and subsequently switch it off.
Button P4 Confirm / Menu.
Button P5 Back / Ventilation ON - OFF
12
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor Costanza at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor Costanza in the language / languages: English as an attachment in your email.

The manual is 3.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor Costanza

Eva Calor Costanza User Manual - German - 27 pages

Eva Calor Costanza User Manual - French - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info