Changing set room temperature
Press button P2 to change the set room temperature. The display shows the current SET temperature value.
It changes the appliance's temperature setting
Press button P1 to change the set room temperature. The display shows the current SET temperature value.
External thermostat/chrono-thermostat use
If you want to use an external programmable thermostat, connect it to the TERM clamps (connector CN7 pin 7-8).
External thermostat
External chrono-thermostat
Enable the thermostat by setting the room temperature below 7°C when T-E appears.
The stove external thermostat is enabled when the contact is closed with stove on.
Room temperature reaches the set value (SET temperature)
When the set room temperature value is reached or the fume temperature has reached the safely value, the stove heat output is set automatically to the minimum
value, MODUL- mode.
If the stove is in the GO STBY mode, it switches off with a delay equal to a pre-set time after reaching the SET temperature. Restart occurs following the state in
which the room temperature has dropped.
Cleaning the burn pot
Depending on working activities of the heater, it is needed to manually clean the brazier to ensure maximal efficiency and standard functioning of the unit.
Switching off the unit.
To switch off the appliance simply press the P4 button for approximately 2 seconds. The auger tube stops immediately and the exhaust blower reaches its maximum
speed. The C phase is performed.
At the end of the period of time set when the fume temperature has fallen below the set value, the exhaust blower stops.
Stove Off
The display will show the wording OFF. The exhaust blower stops.
Stove re-ignition
It will be possible to switch the stove back on only at the end of the safety period of time set and if the fume temperature has not cooled.
WHAT HAPPENS IF...:
Pellet ignition failure
In case of non-ignition, the display shows the alarm message “NO IGN”.
Power outage
Pr48 = 0
When the power is resumed after an outage, the stove enters the CLEANING FINAL phase and waits until the fume temperature reaches a value below Pr13.
Pr48 = T seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
power outage duration
new status
switched off any switched off
ignition < T ignition
pellet loading without pre-load < T pellet loading
pellet loading with pre-load any switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning < T burn pot cleaning
switching off < T switching off
If the power outage duration is longer than T, the stove switches off.
12. ALARMS
In the event of a malfunction, the control board indicates the problem and activates various procedures depending on the type of alarm. The possible alarm
messages are listed below:
Display shows No. Cause
BLACK-OUT (1)
Absence of mains voltage
PROBE EXHAUST (2) Fume temperature probe fault
HOT EXHAUST (3) Fume overheating
FAN FAILURE (4) Exhaust blower fault, not working
NO LIGHTIN- (5) Stove does not ignite
NO PELLET (6) Shutting down due to insufficient pellets
SAFETY THERMAL (7) Safety thermostat activated
FAILURE DEPRESS (8) Depressor activated
TRIAC COC FAILURE (AL B) The auger tube turns continuously
GUASTO PULITORE (AL C) The burn pot cleaner is blocked
In case of alarm, the stove is immediately switched off.
Alarm status can be reset by pressing the P4 button.
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eva Calor ARIA 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eva Calor ARIA 50 in the language / languages: English as an attachment in your email.

The manual is 7.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eva Calor ARIA 50

Eva Calor ARIA 50 User Manual - German - 31 pages

Eva Calor ARIA 50 User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info