749195
22
Zoom out
Zoom in
Previous page
1/48
Next page
22
IP2288EN
EN
Output Value of
accessories Description
RDX 6ZENRS
ZENPRS
The control panel is fitted with a housing for modules of the 6ZENRS
radio receiver type (433.92 MHz).
Can be replaced with a module of the ZENPRS radio receiver type (868.35
MHz).
When using slot-in radio boards, remove the RDX module. The display
will show .
WARNING: the modules must be inserted and removed with the power
supply disconnected.
COM
BIXM R2
COM - This allows the functioning congurations to be saved using the
function .
The saved configurations can be recalled using the function .
COM - The storage module allows the remote controls to be stored. If the
control panel is replaced, the storage module being used can be inserted
in the new control panel.
WARNING: the storage module must be inserted and removed with
the power supply disconnected, and paying attention to the positioning
direction.
BAT
SBU
BAT - Battery-powered operation.
The batteries are kept charged when the power supply is on. If the power
supply is off, the panel is powered by the batteries until the power is re-
establish or until the battery voltage drops below the safety threshold.
The control panel turns off in the last case. WARNING: the batteries must
always be connected to the control panel for charging. Periodically check
the efficiency of the batteries.
NB: the operating temperature of the rechargeable batteries is from
+5°C to +40°C.
For advanced control of battery-powered operation, refer to the menu .
Jumper Description 130 130
JR5 Selection of power supply - auxil-
iary board.
AUX1 powered from 0-1.
(default)
AUX1 powered from 0-30.
Jumper Description OFF ON
JR1 Display mode selection. Display mode.
Only the values and pa-
rameters present can be
displayed.
Maintenance mode.
Only the values and pa-
rameters present can be
displayed and modied.
Activated maintenance
mode is indicated by the
permanent switching on of
the right-hand point on the
display.
14. Jumper setting
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec ION6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec ION6 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info