IP2288EN
EN
17. Troubleshooting
Problem Possible cause Alarm
signalling
Operation
The control panel
does not switch on
No power supply. Check the power supply cable and the
relative wiring
The automation
does not open or
close.
No power. Check power supply cable.
Short circuited accessories Disconnect all accessories from termi-
nals 0-1 (a voltage of 24V= must be pre-
sent) and reconnect them one at a time.
Contact Technical Service
Blown line fuse. Replace fuse.
Safety contacts are open. Check that the safety contacts are closed
correctly (NC).
Safety contacts not correctly
connected or self-controlled
safety edge not functioning
correctly.
Check connections to terminals 6-8 on
control panel and connections to the
self-controlled safety edge.
Photocells activated. Check that the photocells are clean and
operating correctly.
The automatic closure does
not work.
Issue any command. If the problem per-
sists, contact Technical Service
Motor fault Check motor connection, if the problem
persists, contact Technical Service.
Mechanical fault Check the rack and transmission chain,
and/or the mechanical parts.
Release microswitch open Check that the hatch is closed correctly
and the microswitch makes contact.
Faulty control panel
Contact Technical Service
Both limit switches are active. Check the connection of the limit
switches.
The external safety
devices are not ac-
tivated.
Incorrect connections be-
tween the photocells and the
control panel.
Check that / is displayed
Connect NC safety contacts together in
series and remove any jumpers on the
control panel terminal board.
Check the setting of and
.
The automation
opens/closes
briefly and then
stops.
There is a presence of friction. Manually check that the automation
moves freely and check the /
adjustment
Contact Technical Service
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec ION6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec ION6 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info