IP1967EN - 2015-09-08
Display Description
SM - Selection of the operating mode of photocell terminals
1-6. (only with ).
00 - During manoeuvre, the opening of the safety contact
stops movement with disengagement.
01 - During manoeuvre, the opening of the safety contact
stops movement with disengagement. When the contact
is reclosed the interrupted manoeuvre resumes.
02 - During manoeuvre, the opening of the safety contact
stops movement with disengagement. When the contact
is reclosed an opening manoeuvre starts.
03 - During a closing manoeuvre, the opening of the safety
contact reverses the movement.
STOP +
DISENGAGE
STOP +
OPENING
STOP +
RESUME
REVERSE
CLOSING
TN - Setting intervention temperature for NIO anti-freeze
system. [°C]
Adjustment of the working temperature of the control
panel.
DOES NOT refer to outside temperature.
-6 ºC +6 ºC
TB - View control panel temperature.
DO NOT USE
OFF ON
OL - Selecting open gate indicator light mode.
When set ON, the light is switched off when automation is
closed; it is switched on when automation is open and during
the opening and closing phases.
When set OFF the light is switched off when automation is
closed; it is switched on when automation is open , it flashes
during the opening and closing phases.
FLASHING ON
i
WARNING: it is possible that, owing to the type of automation and control panel, certain
menus are not available.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec E2H - IP1967 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec E2H - IP1967 in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec E2H - IP1967

Entrematic Ditec E2H - IP1967 Additional guide - English - 2 pages

Entrematic Ditec E2H - IP1967 Additional guide - German - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - German - 36 pages

Entrematic Ditec E2H - IP1967 Additional guide - French - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info