609376
25
Zoom out
Zoom in
Previous page
1/36
Next page
63
IP1967EN - 2015-09-08
Display Description
TP - Setting of automatic closing time after partial ope-
ning. [s]
Adjustment occurs with intervals of varying sensitivity.
- from 0 to 59 sec with 1 sec intervals;
- from 1 to 2 min with 10 sec intervals.
0 SECONDS
1 MINUTE
59 SECONDS
2 MINUTES
PO - Approaching/deceleration speed during opening. [V]
MIN MAX
PC - Approaching/deceleration speed during closing. [V]
MIN MAX
OB - Deceleration/braking time during opening. [s]
MIN MAX
CB - Deceleration/braking time during closing. [s]
MIN MAX
DS - Setting of display viewing mode.
00 - No display
01 - Commands and safety devices with radio test (see
paragraph 10.2)
02 - Automation status (see paragraph 10.1)
03 - Commands and safety devices (see paragraph 10.2)
NONE
STATUS
RADIO TEST
COMMANDS
D6 - Selecting device connected to terminals 1-6.
NO - None
SE - Safety edge
PH - Photocells
NONE
PHOTOCELLS
EDGE
D8 - Selecting device connected to terminals 1-8.
NO - None
SE - Safety edge
PH - Photocells
NONE
PHOTOCELLS
EDGE
NOTE: setting 01 allows to view the reception of a radio
transmission for checking its range.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec E2H - IP1967 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec E2H - IP1967 in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec E2H - IP1967

Entrematic Ditec E2H - IP1967 Additional guide - English - 2 pages

Entrematic Ditec E2H - IP1967 Additional guide - German - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - German - 36 pages

Entrematic Ditec E2H - IP1967 Additional guide - French - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info