IP1967EN - 2015-09-08
Display Description
CV - View total manoeuvres counter.
= 241.625 manoeuvres (example)
CA - Setting the maintenance alarm interval. (max 500.000 partial manoeuvres)
= 08 08 50 00 = 85.000 manoeuvres (ex)
= 50
= 00
It is possible to set the required number of operations for the signalling of the mainte-
nance alarm.
OA - Selecting maintenance alarm viewing mode.
00 - Display
(display alarm message )
01 - Flashing light
(when automation is closed it flashes 4 times every 60
minutes)
02 - Open gate indicator light
(when automation is closed it flashes 4 times every 60
minutes)
DISPLAY
INDICATOR
FLASHING
CP - View partial manoeuvres counter.
= 71.625manoeuvres (example)
ZP - Resetting partial manoeuvres counter.
To ensure correct operation, it is recommended to reset the partial manoeuvres counter:
- after each maintenance intervention,
- after each setting of the maintenance alarm interval.
2 s
(
EXAMPLE
)
(
EXAMPLE
)
2 s
9.9 Second level menu - CC (Cycles Counter)
- use the keys S and T to select the required function
- press the ENTER key to confirm
The procedures to activate the functions are described in the table.
i
Note: view only.
i
i
Note: view only.
Warning: it is possible that, owing to the type of automation and control panel, certain
menus are not available.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec E2H - IP1967 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec E2H - IP1967 in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec E2H - IP1967

Entrematic Ditec E2H - IP1967 Additional guide - English - 2 pages

Entrematic Ditec E2H - IP1967 Additional guide - German - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - German - 36 pages

Entrematic Ditec E2H - IP1967 Additional guide - French - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info