609376
28
Zoom out
Zoom in
Previous page
1/36
Next page
66
IP1967EN - 2015-09-08
1-5 - Step-by-step command.
1-6 - Safety with opening and closing stop.
1-8 - Safety with closing reversal.
1-9 - STOP command.
P3 - Partial opening command.
3P - Hold-to-run opening command.
4P - Hold-to-run closing command.
RX - Radio reception (of any memorised transmitter key present in the memory module).
NX - Radio reception (of any key not memorised).
CX - AUX coupling board command reception.
F1 - Generic limit switch relating to motor 1.
F2 - Generic limit switch relating to motor 2.
O1 - Detection of an obstacle by motor 1 or arrival of motor 1 at mechanical stop.
O2 - Detection of an obstacle by motor 2 or arrival of motor 2 at mechanical stop.
RV - Enablement/disablement of built-in radio receiver via JR5.
MQ - Acquisition of mechanical stops in progress.
HT - Heating of the motors (NIO function) in progress.
J1 - Variation of the JR1 jumper status.
1C - Closing manoeuvre 1 wing at a time.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Ditec E2H - IP1967 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Ditec E2H - IP1967 in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Entrematic Ditec E2H - IP1967

Entrematic Ditec E2H - IP1967 Additional guide - English - 2 pages

Entrematic Ditec E2H - IP1967 Additional guide - German - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - German - 36 pages

Entrematic Ditec E2H - IP1967 Additional guide - French - 2 pages

Entrematic Ditec E2H - IP1967 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info