chassis of the car. Please use a piece of metal or screw remote from the battery or
fuel line.
• When you are sure the battery leads are correctly placed, connect the power cord to
the power outlet. Once you have connected the AS1210 battery charger to AC power,
the power LED will light up. When connected to the rating supply, the device will
reset itself automatically at the very beginning, and stays at standby state if there is
no battery connected by the user.
• The flashing of the charging LED’s ”CHARGING” will now indicate charging (depending
on the charging stage) or the permanent illumination of the LED “FULL” will indicate
that the battery is fully charged.
Reverse Polarity
If the DC battery clamps are connected improperly to the battery terminals, the reverse
polarity LED will indicate the reversed polarity. If this occurs simply disconnect the
battery charger from the AC power. Connect the DC clamps correctly to the battery
terminals. Reconnect the charger to the AC power.
Pulse rescue dead battery
When being connected to a battery and starting the charging course, the charger detects
the voltage of the battery automatically and then changes to pulse charging mode
(recovery mode) if the voltage is within the range of from 4.5V±0.5V to 10.5V±0.25V for
12V battery. This pulse charging course won’t stop until the battery voltage rises to
10.5V±0.25V.
If pulse charging rescued battery over 7 hours the battery voltage below 10.5V±0.25V
for 12V battery, the charger will return to Standby mode.
Once the battery voltage has reached the value of 10.5V±0.25V, the charger changes to
the normal charging mode and now the battery can be charged up fast and safely.
Through this method, most of dead batteries can be rescued.
LED display
Via the LED’s on the battery charger you can see the charging stage: