7
|
ENGLISH
software to send an email as soon as a problem with the power supply occurs. Enter
the correct mail address information and select the event which will trigger the email to
be send.
You can also change the settings for the auto Shutdown function which enables you to
automatically save data, close programs and shutdown the computer as soon as a
problem with the power supply occurs.
The ‘Setup alarm window information’ button enables you to enter warning messages
which will appear as soon as a specified problem occurs.
Event Log
Here you can view the log files generated by UPSmart 2000I. The ‘List’ tab displays all
logs with date, time and a description. You can save, print or remove these logs.
Close files
The files and programs which have been automatically saved and closed by UPSmart
2000I can be viewed here.
UPS Control
This allows you to perform several self-tests
About
Here you can find certain information about UPSmart 2000I, such as the version and
the serial number.
4.0 Windows Power Options
Instead of running UPSmart 2000I or UPSmart 2000R you can also use Windows
Power Options to manage the UPS, if your UPS is an EM3980 or EM3982. Windows
2000 and XP are equipped with a built-in support for UPS’s. Windows Vista does not
support UPS’s with serial ports. The UPS models EM3984 and EM3988 are not
compatible with the Power Option software.
In this chapter we will explain how you can configure and manage the UPS using the
built-in support of Windows XP.
4.1 Connecting the UPS
After the UPS has been connected you will need to indicate to which COM port it has
been connected for Windows to be able to recognize and manage the UPS. Follow the
instructions below:
1. Click the Start button.
2. Click ‘Control Panel’.
3. Click ‘Power Options’.