741486
8
Zoom out
Zoom in
Previous page
1/20
Next page
(((ELKRON)))
MP110 USER MANUAL
(((ELKRON)))
MP110 USER MANUAL
2.1 Storage of a New Key
1. Enter the MASTER USER code on the keypad and press keys
F
+
7
in sequence.
2. Press th
1
key several times until the following message appears
on the display:
• keypad with alphanumeric display:KEY PROGRAM
• keypad with segmented display: - (one flashing hyphen)
3. Press the
7
key. Commutator led 2 flashes slowly to indicate
system standby for entry of the first key.
4. Insert the commutator key. The system proposes key enabling on all
three zones with the lighting of leds 1, 3 and 4. If this is the desired
configuration, remove the key while led 2 flashes quickly.
5. By leaving the key permanently inserted, the various combinations of
zones with which the key can be associated are displayed with the
lighting of leds 1, 3 and 4, as shown in the table below:
6. When the desired combination has been set, remove the key ONLY
WHILE LED 2 FLASHES QUICKLY.
7. Re-insert the key. If the operation has been successfully
performed, the leds of the zones previously associated with the key
will light up and led 2 flashes slowly while standing by for the
programming of any other keys.
slow
flashing
led 1, 3
and 4 ON
1 1 ON 3 ON 4 ON the key is associated with all 3 zones
2 1 ON 3 OFF 4 OFF the key is associated with zone1
3 1 OFF 3 ON 4 OFF the key is associated with zone 2
4 1 ON 3 ON 4 OFF the key is associated with zones 1and 2
5 1 OFF 3 OFF 4 ON the key is associated with zone 3
6 1 ON 3 OFF 4 ON the key is associated with zones 1and 3
7 1 OFF 3 ON 4 ON the key is associated with zones 2 and 3
33
3.6 Disarming with Antirobbery Code
If the system is equipped with an integrated telephone unit or other remote
transmission system, a panic alarm signal can be sent in case of constraint
to disarm the antirobbery system.
The disarming procedure described in para 3.1 is carried out, but it is
necessary to enter the secret code increasing the last digit by one unit.
Example: code 123456 would become 123457; code 132459 would
become 132450.
Disarm the control unit; if within approx.30 sec the correct code is not
entered the control unit will send the panic alarm to all programmed
telephone numbers.
3.7 Wrong Code
In case of introduction of a wrong code for 4 consecutive times, the
system visualizes a tamper on the keypads and the readers. When
introducing a wrong code for the fifth consecutive time, the system starts
a tamper alarm.
3.3 Arming with Reduced Code
It is sufficient to enter the first 2 digits of the code followed by key
TOTAL
for a total arming, or
1
,
2
or
3
for a partial arming.
Quick arming is possible only if the system is fully disarmed.
3.4 Commutating Lock with Open Zones
If the commutating lock with open zones has been programmed, it will
not be possible to arm –neither from keypad nor by DK key – the sectors
to which the currently open zones are associated. If you try such an
arming from keypad, a relevant warning is provided on the display and
no arming will take place.
3.5 Open Zone Self-Bypassing
If both commutating lock and self-bypassing have been programmed,
the zones left open are automatically bypassed when an arming from
keypad or DK key is carried out. If the arming is made from keypad, the
self-bypassing is properly signalled on the display. The arming regularly
takes place and no alarm is generated. The self-bypassed zones are
reentered automatically at their re-closing (even with armed system).A
following opening will therefore generate the alarm.
8
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110M in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110M

Elkron MP110M User Manual - German - 32 pages

Elkron MP110M User Manual - French - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info