3.System Arming/Disarming
For ARMING of the system, enter a valid code and press the
TOTAL
key.
all sectors referred to the entered code will be armed. The leds
corresponding to the armed sectors will flash and then turn on in a fixed
mod
If an exit delay occurs, it is indicated by the buzzer with an intermittent
signal .
•To DISARM the system, enter a valid code and press the
TOTAL
key.
Leds
1
3
,
2
and
3
are turned OFF and the buzzer
beeps twice.
To partially ARM the system, enter a valid code and press the key for
the zone or zones one wishes to arm.
1
to arm Zone 1 - the led
1
3
flashes and lights up with a fixed
light after 4 seconds.
2
to arm Zone 2 - the led
2
flashes and lights up with a fixed
light after 4 seconds.
3
to arm Zone 3 - led
3
flashes and lights up with a fixed light
after 4 seconds.
To DISARM the system, enter a valid code and press the
TOTAL
key. The
leds of the previously armed zones are turned OFF and the buzzer
beeps twice.
During partial arming, about 5 seconds are available (led flashing time)
within which it is possible to correct the type of arming; once this time
is up, the leds light up with a fixed light and the sectors are armed.
After selecting the desired configuration for the zones, arming can be
confirmed by pressing the
A
key without waiting for the time
available for arming to expire.
3.1 Arming/Disarming
3.2 Partial Disarming
7
If the operation was not successfully performed (for example, because
the key was not removed while led 4 flashed quickly), all leds will flash
quickly to indicate that the operation has failed and that the programming
operation must be repeated. In this case, the message “PROGRAM
ERROR” appears on the alphanumeric display, while the symbol “-”
appears on the led display and all three zone leds flash.
8. Remove the key. Return to item 4 to program the other keys or press
key
F
to exit
2.2 Addition of a Key
1. Enter the MASTER USER code on the keypad and press keys
F
+
7
in sequence.
2. Press the
1
key several times until the following message appears
on the display:
• keypad with alphanumeric display:KEY ADDITION
• keypad with segmented display :
a
(flashing)
3. Press the
7
key. Commutator led 2 flashes slowly to indicate
system standby for entry of the additional key.
4. Proceed in the order described in items 4, 5, 6, 7 and 8 of the previous
section to associate the desired sectors to the key.
2.3 Duplication of a Key Code
1. Enter MASTER code on keypad and press keys
F
+
7
in
sequence.
2. Press key
1
several times until the display shows the following
message:
keypad with alphanumeric display: “READ KEY CODE
keypad with segment display: “
L
” (flashing)
3. Press key
7
. Led 2 of the commutator flashes slowly to show that
the system is waiting for the introduction of the key to be duplicated.
4. Introduce the key to be read. After approx. 2 seconds a double beep
will be generated to confirm that the code has been read. The procedu-
re is terminated and the system has stored the key code. Press key
F
to exit. To make the desired keys operating, follow the procedu-
re “ Addition of a key” , para 2.2.
34
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron MP110M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron MP110M in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron MP110M

Elkron MP110M User Manual - German - 32 pages

Elkron MP110M User Manual - French - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info