8 DS80IR1F-001C
Ceiling mounting:
Mount the detector on the ceiling to monitor the crossing of an area in front of a window or a door.
If mounted at a height from 2.4 to 3 m from the ground and oriented downwards, the detector has a coverage of
approximately 5 m from floor level.
Avoid mounting over 4 metres high because this could compromise the correct functionality of the detector.
The arrows show the intrusion movements which are detected in the various mounting positions.
Installation
Choose the position of the detector, i.e. either horizontal, vertical or on the ceiling.
After having selected the installation position, follow the procedure described above to mount the detector.
Press the Test button to enter Test mode. Move in the protected area and observe when the LED lights up to check that
the detection coverage is adequate.
Installation is complete when the detection coverage is appropriate.
Installation advice
<IMPORTANT>
Before choosing the height at which to install the detector, consider that a blind area is present under the detector;
this area widens proportionally to the height at which the detector is positioned.
It is worth noting that the performance of the detector may be conditioned by external factors, such as the height of
the detected objects, the area to be detected, the installation point etc. The suggested installation height may be
adjusted according to the environmental factors found.
Take the following guidelines into consideration to optimise detector use:
Mount it in a position in which an intruder would normally cross the field of vision of the detector from one side to the
other.
Mount it where the field of vision is not obstructed, e.g. by curtains, ornaments etc.
Restrictions
Do not position the detector directly facing a door protected by the door contact because the wireless signals of the
door contact and of the detector could be transmitted in input at the same time, causing the signals to cancel each
other out.
Do not install the detector fully exposed to direct sunlight.
Do not install the detector in areas in which devices which could cause sudden changes of temperature in the
detection area are present, such as air conditioning units, radiators etc.
Avoid large size obstacles in the detection area.
Do not point directly towards source of heat, such as fires or boilers, and do not install over radiators.
Avoid moving objects in the detection area, i.e. curtains, soft furnishings etc.
Technical specifications
Power supply: 1 battery CR123A 3V
Battery life: 3 years (typical value, may vary according to use)
Two-way radio frequency: 868 MHz
Infrared range: max 8 m with 110° angle
Working temperature range -10°C – +45°C
Dimensions: 76 mm x 56 mm x 43 mm
Weight: 300g
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type: CURTAIN-EFFECT INFRARED DETECTOR IRT600 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
www.elkron.com
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron IRT600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron IRT600 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron IRT600

Elkron IRT600 Quick start guide - English, German, French, Italian - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info