741428
6
Zoom out
Zoom in
Previous page
1/17
Next page
6 DS80IR1F-001C
ENGLISH
The IRT600 detector with passive infrared (PIR) motion sensor capable of detecting movements in an assigned area and indicate
them to the control unit to activate the intrusion alarm. The base of the product is provided with holes for installing it on a flat
surface or in a corner.
The detector has a single tamper micro switch which is activated when the lid is opened. Furthermore, it can send a warning to
indicate a communication problem or flat battery conditions. The detector is designed to work within a detection field of 8 metres.
Component identification
1. IR sensor lens
2. LED indicator
The LED indicator is insert the front cover and can only been seen when it is on.
3. Battery housing
The detector uses a CR123A (3V) battery
4. Micro tamper switch
The micro tamper switch protects the detector from unauthorised opening of the cover and
removal from the installation surface.
5. Test / Learning button
The Test button is used to test wireless communication performance and to carry out the learning
procedure of the device by the control unit.
6. Jumper for increasing sensitivity (JP3)
- If the jumper is set to OFF (if the jumper connection is removed or positioned on only
one pin), the detection sensitivity is at normal level (default).
- If the jumper is set to ON, the detection sensitivity of the detector is maximum.
7. Battery isolator
Sleep Time
The detector has a sleep time of approximately 1 minute to save energy. After having
transmitted a detected movement, the detector will not transmit again for 1 minute; any further
movements detected during the sleep period will extend the sleep period by another minute. In
this way, continuous movements in front a detector will not drain the battery unnecessarily.
Supervision function
When the detector is in normal operation mode, it runs a periodically self-diagnostic test, transmitting a supervision signal at
constant intervals.
A supervision alarm is generated if the control unit does not receives supervision signals transmitted by a given detector for
a predetermined time.
Sensitivity Increaser function
This function can be used to increase detection sensitivity. Position the Jumper (JP3) in ON to increase detection sensitivity.
Leave the Jumper (JP3) in the OFF position to keep the default detection sensitivity.
Test mode
The detector can be set to Test mode by pressing the Test button for a few seconds. In Test mode the sleep timer will be
deactivated and the LED indicator will blink whenever movement is detected. Whenever the Test button is pressed, the
detector transmits a test signal to the control unit to test the wireless communication range and goes to Test mode for 3
minutes. It automatically exits Test mode after 3 minutes and goes back to normal mode.
LED indicator
In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations.
When movement is detected in flat battery conditions.
When the cover is opened and the micro tamper switch is actuated.
When movement detected if the tamper alarm condition persists.
When motion is detected in Test mode.
When the Test button is pressed in tampering conditions or if the battery of the detector is flat.
The LED does not blink if the tamper switch and the battery detector are in normal conditions and not in Test mode.
The LED blinks rapidly twice to confirm reception by the control unit.
Battery
The motion sensor is powered by a CR123A lithium battery.
The detector can detect low battery state. When a flat battery is detected, a signal is sent to the control unit together with the
normal signal transmission for the control unit to view the corresponding state.
The battery is installed at the factory with the isolator inserted.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron IRT600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron IRT600 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron IRT600

Elkron IRT600 Quick start guide - English, German, French, Italian - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info