<NOTE>
While replacing the batteries, after having removed the flat batteries, press the micro tamper button twice to
discharge the device completely before inserting the new batteries.
Preparation
Extract the battery isolator to activate the battery,
The LED will blink for 30 seconds (the detector is being initialised). During initialisation, the detector will not be activated.
It is advisable not to generate any alarms during this time. Once the initialisation time has finished, the LED will switch
off and the detector is ready to start working.
Enable the control unit to run the device learning procedure. Refer to the control unit instruction manual for details.
Open the casing and press the Test button.
Refer to the instruction manual of the control unit to complete the learning process.
After having integrated the detector, set the control unit to “Walk Testmode: keep the detector in the required position
and press the Test button to confirm that the concerned position is within the communication range of the control unit;
see the control unit instruction manual to complete the Walk Test.
Proceed with the installation after having ascertained that the detector is working in the desired position.
Infrared detection coverage
When it is mounted in vertical position, the detector has a frontal detection coverage range of 10° on the horizontal plane
and of 110° on the vertical plane.
The detector is only activated by movements in the 10° horizontal coverage area.
The detector may be mounted vertically or horizontally on the surface of the wall or to the ceiling. Different installation
methods from that described imply different detection coverages (see further details in the next paragraph).
Mounting method
The detector was designed to be mounted on a flat
surface, on a wall or in a corner using the fixing screws
and the anchor bolts provided.
If the detector is forcefully removed from the surface on
which it is installed, the tamper switch pre-cut area will
detach from the detector remaining attached to the
surface and the detector will generate an alarm.
Hole arrangements are provided on the base where the
plastic is thinner and may be broken.
I. Release the cover from the base levering with a
slot screwdriver in the housing provided for the purpose.
II. Perforate the appropriate hole arrangements on the inner side of the base.
III. Using the bases as template, make the holes in the surface.
IV. Insert the anchor bolts if the device is fixed to plaster or bricks.
V. Screw the base into the anchor bolts.
VI. Reposition the cover on the base inserting the upper coupling of the cover in the specific slot provided on the
base first.
The detector may be installed either vertically or horizontally or onto the ceiling. Each method implies different applications,
illustrated below.
Vertical wall mounting:
The detector is designed to cover an 8 metre curtain area when it is installed from 1.4 to 1.7 metres from the ground.
Avoid mounting over 1.8 metres high because this could compromise the correct functionality of the detector.
Horizontal wall mounting:
When mounted horizontally, the detector has a detection coverage of 5 metres and only for vertical movements. It
cannot detect horizontal movements. This feature is only useful for detecting intrusions in case of access from the
top, e.g. by means of skylights or hatches on the roof.
Avoid mounting under 2.2 metres high because this could compromise the correct functionality of the detector.
Pre-cut area for
tamper switch Hole
arrangement
for fixing on
surface x 2
8m
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron IRT600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron IRT600 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron IRT600

Elkron IRT600 Quick start guide - English, German, French, Italian - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info