GB
13
27. TIMER DISPLAY: As soon as an activation /
deactivation time has been selected, TIMER ON
or TIMER OFF will appear in this area.
Operating modes
A) AUTO (Automatic) mode
1. Press the MODE button to select AUTO mode.
2. Pressing the TEMP buttons enables you to
select the required room temperature. The most
comfortable temperature settings are between
21°C and 28°C.
3. Pressing the ON/OFF button enables you to
switch on the air conditioner. OPERATION and
AUTO will be lit on the display of the indoor
device. In addition the temperature set on the
remote control will be displayed. The fan speed
will be set automatically.
4. Pressing the ON/OFF button a second time
enables you to switch off the air conditioner.
NOTE
In AUTO mode the air conditioner will automatically
select on the COOL, FAN and HEAT modes by
detecting the temperature difference between the
actual room temperature and set temperature.
B) COOL, HEAT and FAN modes
1. You can select the required COOL, HEAT or
FAN mode by pressing the MODE button.
2. Pressing the TEMP buttons enables you to
select the required room temperature.
3. Pressing the FAN button enables you to select
the fan speed. Each time you press the button,
the speeds will be selected in the following
sequence: AUTO – LOW – MED – HIGH.
4. Pressing the ON/OFF button enables you to
switch on the air conditioner. In addition the
temperature set on the remote control will be
displayed.
5. Pressing the ON/OFF button a second time
enables you to switch off the air conditioner.
NOTE
FAN mode cannot be used to control the
temperature. Only settings 1, 3, 4 and 5 can be
made in this mode.
Information about cooling mode
If the room temperature is approx. 1°C above the
nominal value setting, the air in the room will be
cooled. The inverter control compares the nominal
temperature setting to the current room temperature.
If there is a large difference, a high cooling capacity
will be generated, whilst if the different is only small,
a low cooling capacity will be generated.
The room temperature is thus kept at a constant
level. If the room temperature falls below the nominal
temperature setting by around 2°C, the controller will
shut off the cooling system. The cooling system will
not be switched on again until after a waiting period
of approximately three minutes to protect the
compressor.
Information about heating mode
Heating mode is only designed for spring and
autumn. If the room temperature is approx. 1°C
below the nominal value setting, the air in the room
will be heated. The inverter control compares the
nominal temperature setting to the current room
temperature. If there is a large difference, a high
heating capacity will be generated, whereas if the
different is only small, a low heating capacity will be
generated. The room temperature is thus kept at a
constant level. If the room temperature rises above
the nominal temperature setting by around 2°C, the
controller will shut off the heating system. The
heating system will not be switched on again until
after a waiting period of approximately three minutes
to protect the compressor. To prevent the discharge
of cold air, the fan in the indoor device is only
switched on after a delay (hot air monitor). The fins
on the outdoor device can ice up in low outdoor
temperatures. In this case the outdoor device will be
de-iced.
C) DRY (dehumidifier) mode
1. Press the MODE button to select DRY mode.
2. Pressing the buttons enables you to select
the required room temperature.
3. Pressing the ON/OFF button enables you to
switch on the air conditioner. The temperature
set on the remote control will be displayed.
4. Pressing the ON/OFF button a second time
enables you to switch off this mode.
Information about dehumidifier mode
The dehumidifier function is most effective if the
room temperature is set to 24°C and the fan speed is
set to AUTO. The fan is switched on and off at
intervals in this mode.
D) TIMER mode (0.5 – 24 hours)
Press the TIMER ON button to set the automatic
activation time for the device or the TIMER OFF
button to set the automatic deactivation time for the
device. Press the ON/OFF button to cancel the
activation or deactivation time.
Setting the activation time
1. Press the TIMER ON button. The remote control
display will now show TIMER ON, the last time
set for the starting the device and the “hr”