ENGLISH
Building protection
All the building surfaces near the hearth
must be protected against heat. The type
of insulation to be adopted depends on the
type of surfaces present and how they are
made.
Hot air outlets / Grills
The hot air outlets must be placed at a
minimum distance of 50 cm from the
ceiling and 30 cm from the furniture.
Position the grills or the air outlets at the
highest point of the covering, in order to
avoid heat accumulating inside the same
covering. Position the grills or the air outlets
so that they can be easily accessed for
cleaning.
Heating insulation
The insulating layers must not have joints
and have to be overlapped. The thickness
of the insulating material must be of at least
3 cm.
Ornamental beams
The realisation of eventual wood
ornamental beams in front of the hearth
covering is allowed only if they are outside
the radiation field, at a distance of at least
1 cm from the same covering. The air space
between the ornamental elements and the
covering must be such not to accumulate
heat.
The wood ornamental beams cannot be
integrating parts of the building.
Floor opposite the hearth
The floors built with fuelling materials
must be protected by sufficiently thick, non
fuelling cover, or must be replaced with a
non fuelling floor. The floor protection must
be equal to:
frontally:
- the corresponding height of the fire
surface from the floor plus 30 cm and, in
any case, min. 50 cm
laterally:
- the corresponding height of the fire
surface from the floor plus 20 cm and, in
any case, min. 30 cm.
In the radiation eld of the
hearth
The structural elements built with fuelling
material or which present fuelling
components and the furniture must be
positioned at a minimum distance of 80
cm from the hearths mouth, in all three
directions: front, upper and side. Whenever
such elements or furniture were screened by
a ventilated anti-radiation protection, it will
be sufficient to respect a distance of 40 cm.
Outside the radiation eld
The structural elements built with fuelling
materials or which present fuelling
components and the furniture, must be
positioned at a minimum distance of 5
cm from the hearths covering. In such
air space, the air present in the room
must be able to circulate freely. No heat
accumulation must be created.
Electric lines
There must be no electric lines in the walls
and the ceilings, including the hearth
embedding area.
INSTALLATION INSTRUCTIONS
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Double at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Double in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info