35
HYDRAULIC CONNECTIONS
(Reserved for DEALER)
The stoves have a boiler with a capacity of 80 Lts. of water. This significant amount of water renders the stove extremely smooth in
operation, little affected by variations in demand of users. This will provide for highly consistent combustion with excellent yield .
The stoves are equipped with a kit for producing instant Domestic Hot Water for bathrooms and kitchens as well as kits for the hea-
ting system (circulator, safety, loading and unloading). The stoves are also equipped with a solenoid valve that, in the start-up phase
plays a very useful RECIRCULATION function; moving the water inside the stove, and speeding up the heating phase.
The hydraulic connection must be performed by qualified personnel who can issue a declaration of conformity according to the
Ministerial decree no. 37 ex L.46/90. Reference must however be made to the laws in force in the individual countries.
Water treatment
Foresees the addition of antifreeze, de-scaling and corrosion substances. In the event that the water used for filling and toping up has
a hardness greater than 35° F, use a water softener. For suggestions please refer to regulation UNI 8065-1989 (Water Treatment In
Heating Systems For Civil Use).
The following is a schematic diagram of the hydraulic kit built into the stove for instant production (without accumulation) of ACS.
Circulator
The Ottawa is equipped with a circulator with a new
generation electronic motor.
3-way valve
Safety Valve
Flow meter
Plate heat exchanger
THE ELECTRONIC CIRCULATOR
The Ottawa is equipped with a circulator with a new generation electronic
motor.
Electronic control of operation:
a) Control mode Δp – c
In this mode, the electronic controller keeps the differential pressu-
re generated by the pump at a constant set value of H s.
b) Control mode Δp – v
In this mode, the electronic controller varies the pressure differential between
the set value Hs and 1/2 Hs. The pressure differential varies with the volume
flow.
c) Venting procedure
This procedure allows the expulsion of air present in the hydraulic circuit.
After manual selection of the "AIR" mode, the pump will automatically alter-
nate between maximum and minimum speed for 10 minutes. At the end of the
procedure, the circulator will go to the pre-set speed. You can then select the
desired mode of operation
Pressure differential
Volume flow
Pressure differential
Volume flow
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin ATLANTA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin ATLANTA in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info