33
Smoke thermocouple
placed on the smoke exhaust pipe to detect the temperature. It controls the ignition phase and if the temperature is too high or too low
it triggers a block phase (Stop Flame or Overheated Smoke).
Feed Screw safety thermostat
placed near the pellet hopper. It disconnects the electrical supply to the gear motor if the temperature detected is too high.
Water temperature sensor
detects the water temperature in the thermo-stoves and transmits this to the information card to manage the pump and adjust the power.
If the temperature is too high, a block phase is triggered.
Water overheating safety thermostat
detects the water temperature in the thermo-stoves. If this is too high, it triggers the shutdown process by disconnecting the electrical
supply to the gear motor. In the event that the thermostat has been operated, it must be re-activated by acting on the reset button behind
the thermo-stoves (see page. 52).
Overpressure valve
upon reaching the pressure stipulated on the plate, the system is triggered to discharge the water and consequently the water must be
topped up.
WARNING!!!! remember to carry out the connection with the sewage system.
Manometer
placed on the side of the thermal thermo-stoves (at the rear for the Ottawa model), it allows you to read the water pressure in the ther-
mal thermo-stoves. With the thermal thermo-stoves running, the recommended pressure is 1bar (see page. 42).
Microswitch door opening detection (Boston - Detroit - Miami - Atlanta)
Electro-hydraulic pressure switch (Boston - Detroit - Miami - Atlanta)
IF THE THERMAL THERMO-STOVES BLOCKS, THE REASON WILL APPEAR ON THE DISPLAY AND THIS WILL BE SAVED.
Resistance
triggers pellet combustion. It remains on until the smoke temperature increases by 15 °C from that prior to ignition.
Smoke extractor
"pushes" the smoke into the flue and draws out combustion air via a vacuum.
No. 2 Gear motors
Activate the Archimedes' screw allowing the transportation of the pellets from the storage tank to the crucible.
Pump (circulator)
"pushes" water toward the heating system.
Closed expansion tank
‘absorbs’ changes in the volume of the water contained in the thermal thermo-stoves.
A heating technician must evaluate the need to add a second tank to the existing one, depending on total amount of water in the system.
Venting valve:
positioned in the upper part, it allows for the "bleeding" of any air present during the loading of water inside the thermo-stoves.
Drain tap
placed inside the lower part of the thermal thermo-stoves. This is to be opened if the water inside the thermal thermo-stoves must be
emptied.
Incorporated kit for hot tap water
Allows for the production of hot tap water instantaneously, or rather with no accumulation.
SAFETY AND DETECTION DEVICES
COMPONENTS
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin ATLANTA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin ATLANTA in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info