PLEASE NOTE: FVI12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
English
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
The installation of venting must
comply with national codes, local
codes, and the vent manufacturer’s
instructions. Owner must refer to
vent manufacturer’s instructions and
speci cations. Z-Flex information
can be found at www.nova ex.com,
please refer to page 18 for additional
links.
The water heater must be vented to
the outdoors as described in these
instructions. DO NOT connect this
water heater to an existing Vent or
Chimney: it must be vented separately
from all other appliances.
All vent components (adapters, pipe,
elbows, terminals, etc.) should be UL
1738 Certi ed Stainless Steel Venting
Material (e.g. AL29-4C).
The speci ed vent termination must
be used. The termination must be
used. The termination should be a
90° elbow type with screen. (Refer to
page 18).
Use a vent pipe with an
antidisconnection structure.
The use of a High Temperature
Silicone (500° F) may be required to
seal vent connections. To prevent
accidental gas exhaust leakage,
apply a ¼” wide bead approximately
¼” from the end and another bead
against the joint side of the stop
bead.
Follow vent manufacturer’s
installation instructions.
The unit can be vented either
horizontally or vertically.
Vent pipe runs must be adequately
supported along both horizontal and
vertical runs.
The maximum recommended
unsupported span should be no more
than ve (5) feet. Support isolation
hanging bands should be used. DO
NOT use wire. (See diagram below).
DANGER: Failure
to install the vent
adapter and properly
vent the water heater
to the outdoors as
outlined in the
Venting section of
this manual will result
in unsafe operation
of the water heater
causing death, serious
injury, explosion, or
re. To avoid the risk
of re, explosion,or
asphyxiation from
carbon monoxide,
NEVER operate the
water heater unless it
is properly vented
and has adequate
air supply for proper
operation as outlined
in the Venting section
of this manual.
WARNING: Use
UL approved Category
III Stainless Steel vent
material only. No
other vent material
is permitted. Owner
must refer to vent
manufacturers
instructions and
speci cations. Z-Flex
information can
be found at www.
nova ex.com, see
page 18 for additional
links.
WARNING: Refer
to pages 16-17 for
clearances to
combustible material.
If the vent piping passes through a closed space, wrap the vent pipe with in ammable insulation material
that is at least 3/4” thick. DO NOT let the insulation material make contact with ammable materials. A
minimum clearance of 6” between the vent pipe and ceiling should be maintained. Follow local codes.
For maintenance and inspection purposes, the following holes are
required to be made:
• Two (2) inspection openings that allow access to venting. One
( 1) of these openings should be close to where the vent pipe
enters the ceiling. The other opening should be near the vent
termination.
• A ventilation hole with a 16 sq. in. opening should be made at
least every 10 feet.
NOTICE : Vent pipes must be completely insulated with
in ammable material when installed in alcoves, closets, and garages and must not touch any ammable
material.
Venting
2 Degree Downward Slope.
Installation
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp FVI-12 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp FVI-12 series in the language / languages: English as an attachment in your email.

The manual is 5.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info