PLEASE NOTE: FVI12 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT
NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
English
MAXIMUM VENT LENGTH
Owner must refer to vent manufacturer’s instructions and speci cations. Z-Flex information can be
found at www.nova ex.com, please refer to page 19 for additional links.
The system will not operate if there is excessive restriction (pressure
drop) in the venting system. A maximum of 32 feet of vent pipe
may be used provided there is only one 90° elbow in the system. If
additional elbows are required: two elbows can be used with 27 feet,
and three elbows can be used with 22 feet of vent pipe.
A 90° elbow is equivalent to 5 feet of straight pipe. A 45° elbow is
equivalent to 2 feet 6 inches of straight pipe.
The termination elbow does not count as an elbow when
determining total vent lengths.
The vent must be installed with a slight downward slope of ¼” per
foot of horizontal run toward the vent terminal (see diagram below).
This ensures that any condensate formed during operation of the
unit evacuated from the water heater.
A ¼” per foot upward slope is acceptable when it is not possible to
vent with a downward slope, however, a UL approved Category III
Stainless Steel condensate trap MUST be installed at the beginning
of the horizontal run (See page 20 “Typical Horizontal Termination
w ¼” per foot UPWARD Slope” or page 14, “Standard Vertical Vent
Termination” for examples).
Number of
90° elbows
(bends)
Maximum
Length of
Straight Pipe
1
2
3
32’
27’
22’
One (1) 90° Elbow is
Equivalent to 5 Feet of
Straight Pipe
MINIMUM VENT LENGTH
The venting may be as short as 12”,
provided one vent termination is
installed to the outdoors through a
sidewall, one 90° elbow is included in
the installation, and the wall thimble is
installed.
NOTICE: Make sure that the seam
of the vent pipe in horizontal runs
is toward the top of the installation
(see illustration to the left)
Draining the Condensate
In certain conditions, installations in unconditioned space or having long horizontal or vertical
runs may accumulate condensate.
Condensate is known to be acidic; refer to local, state (provincial) or federal codes for proper
handling methods.
In order to prevent condensate from draining back into the water heater, we recommend a
condensate trap and drain to be installed in a horizontal vent section as close as practical to
the water heater vent connection.
Not following proper condensate procedures will void warranty.
Venting
Installation
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp FVI-12 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp FVI-12 series in the language / languages: English as an attachment in your email.

The manual is 5.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info