On the top of the cabinet there is a cut out for jumper placement. The default position of the
jumper is the parking position JP1. You have 3 different status led response positions:
- Default, JP on position JP1: Feedback LED active & Status LED not-active/unused
- JP on position JP2: Feedback LED & Status LED both always OFF
- JP cable on position JP2 with voltage supply within range: Feedback LED & Status LED active
(depending on external voltage being present)
- JP on position JP3: Feedback LED active & Status LED always ON (based on power to IRHUB4)
6. Operation
The IR repeater system should now operate each of the controlled components. When the
system is operating correctly, you should see a Blue "talk-back" LED flash on the front of the
IRLPRO Flush IR Receiver when you aim your hand held remote control(s) at it and press the
buttons.
7. How to avoid and solve possible problems
Although the ebode IR Link Pro Flush is equipped with proprietary eIR
2
x
TM
(pronounced Irex)
Technology, which guarantees a high level of immunity of InfraRed noise from direct sunlight, CFL
lighting and Flat Panel TV’s (including Plasma, LCD and LED), in rare cases, the IRLPRO Flush IR
Receiver may have to be moved to a different location if the unit is picking up unexpected
interference. This interference may, in severe cases, prevent the system from working.
After repositioning, check to see if the IR Link Pro Flush operates the satellite Receiver or other
components. If the IR Link Pro Flush still does not work, reposition the IRED Emitter(s). It may not be
located directly over the component’s InfraRed receiving "window". Consult the owner's manual
of the unit or the manufacturer for the exact location of the InfraRed "window".
IMPORTANT: For installations involving more than two remote rooms, use the services of a
competent professional audio/video installer experienced in InfraRed remote control systems.
Do you still have questions? Please refer to www.ebodeelectronics.eu
8. Technical information
IRLPRO FLUSH IR RECEIVER SPECIFICATIONS
InfraRed modulation frequency bandwidth: 30 - 60 kHz.
Cable length 3m, extendable to max. 300 metres (UTP or equivalent).
Red 3.5mm TRRS plug pin configuration from tip to sleeve:
o Tip = yellow = IR Data
o Ring 1 = black = Ground
o Ring 2 = red = +12VDC
o Sleeve = white = Status
Reception range: Up to 10 meters, depending on local conditions and remote control used.
Reception angle: 45 degrees off axis.
Talkback LED (BLUE). Indicates InfraRed reception only when Emitter(s) are connected.
Status LED (AMBER). Indicates power status of A/V system
Maximum number of directly driven IRED IR Emitters: 4 triple Emitters using the IRHUB4
Connecting Hub. Up to six IRLPRO Flush IR Receivers may be connected in parallel at the
screw terminals input of IR Link IRHUB series connecting blocks (e.g. optional IRHUB2CI and
IRHUB4). Power requirements: 12 volts DC @ 25 mA. Requires 12VDC Power Supply (included).
Dimensions IRLPRO Flush IR Receiver: 50 mm x Ø 16 mm
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ebode IR Link Pro Flush at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ebode IR Link Pro Flush in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info