6.2 Designation of the calling number sequence
6.2.1 Standard sequence
Alarm triggered Calling number 1
Alarm not acknowledged
by called party 1
Calling number 2
alarm not acknowledged
by called party 2 same for calling number 3 to 9
The alarm is acknowledged by pressing DTMF 0 ( section 7.7.5).
The alarm is passed to next party immediately by pressing DTMF 8 or after connection time-out.
6.2.2 How to program calling number sequence
1. Slide function switch to PROG
2. Enter * * 0.
Current calling number sequence will be announced followed by “to modify press * , to stop press #
3. To maintain the current programming, go to point 5. Otherwise enter *. .
4. Enter the desired sequence (max. 9 digits)
5. Slide function switch to OFF
Sample for programming calling number sequence:
a) ’123’ => calling number 1 will be dialled, followed by calling number 2, followed by calling number 3.
b) ’111133322’ => first calling number1 will be dialled (4 call attempts are made), followed by calling number 3 (3 call
attempts are made), followed by calling number 2 (with 2 call attempts).
Notes:
The calling number sequence is factory set to ‘123456789’, but a general reset according to section 10.1 will NOT
RESET the calling number sequence!
In case of an un-programmed or deleted calling number, the calling number sequence will continue with the next
number of the sequence.
If a dialled number is busy and another call attempt is programmed, the waiting period before re-dialling is 30 sec.
If the calling number changes within the sequence, dialling of a new number starts without delay
6.3 How to select user language / How to record individual message
An individual announcement can be recorded as follows:
1. Shift function switch to PROG
2. Enter * * #.
Current individual message will be announced followed by “to modify press * , to stop press #
3. Select language for user announcements: (facultative)
Press key 1 to 4 according to desired user language (i.e. 1=DE/2=FR/3=GB/4=IT)
4. Press * and start speaking
5. Press # to finish recording, max. duration is 12 seconds
New individual message will be announced
6. Shift function switch to OFF
Note:
Repeat step 3 and 5 until you are satisfied with individual message.
6.3.1 Remote recording of individual message during handsfree connection
1. Enter DTMF * * # #
Current individual message will be announced followed by “to modify press * , to stop press #
2. Select language for user announcements: (facultative)
Press DTMF 1 to DTMF 4 according to desired user language (i.e. 1=DE/2=FR/3=GB/4=IT)
3. Start recording by sending DTMF * , start talking (max. 12 s) and finish by sending DTMF # .
New individual message will be announced
4. Wait until the message “Abort” confirms the end of the programming
Note:
Remote recording can be enabled / disabled according to section 10.8.1.
if called party 3 does not acknowledge the alarm, the calling
number sequence is repeated the number of programmed alarm
repetitions times (default value: two alarm repetitions,
programming see section 10.2)
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EasyAlarm CONTROL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EasyAlarm CONTROL in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EasyAlarm CONTROL

EasyAlarm CONTROL User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info