INSTALLATION MANUAL
5.7.1General
The connection dimensions and the minimum length of the discharge system are indicated in Annex 2, table 2.
The appliance should be connected in accordance with the applicable national, local and constructional
(installation) regulations. You should only install the appliance in a well ventilated room which complies with the
applicable national, local and constructional (installation) regulations, in order to guarantee sufficient air supply.
!Caution
When the appliance is installed in a house with a mechanical air extraction system and/or an open kitchen
with cooker hood, you will need a permanent ventilation hole in the room where the appliance is installed;
please observe the gas installation regulations and the local regulations for dimensions and other required
provisions.
No ventilation of the chimney breast is required in case of an existing chimney with a masonry fireplace that
is sufficiently able to absorb the heat. Therefore the ventilation hole in the chimney breast does not apply to
the class 1 chimney in the UK.
5.7.2Connectionoffluegasdischargesystem (if a class 1 chimney is not applicable)
For connection to an existing chimney, a flexible stainless steel discharge pipe is required over the complete
length for the discharge of the flue gases, unless indicated otherwise. A draught increasing hood is recommended
here.
!Caution
Prevent dirt from an existing chimney from entering the flue gas discharge.
Prevent false draught by carefully closing the space between the existing chimney and the discharge
material.
Bends of more than 45 degrees are not allowed in the flue gas discharge system, unless indicated otherwise.
Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and/or
ceiling. If the system is built in (for instance) a cove, it should be made with non combustible material all
around it;
Use heat-resistant insulation material when passing through combustible material.
Use a flue gas discharge system with the correct diameter, and which is provided with the CE mark.
!Caution
Some heat-resistant insulation materials contain volatile components that will spread an unpleasant smell during
a longer period; these are not suitable.
Place the flue gas discharge system as follows:
Ø
Connect the pipe pieces or flexible SS discharge.
!Caution
Make sure that the right insertion length is maintained.
Secure the connections on locations that are impossible to reach after installation by means of self-tapping
screws.
5.8Fluegasdischarge/combustionairsupplysysteminapplianceswithclosed
combustion
5.8.1General
The appliance's type of discharge system is stated in Appendix 2, Table 2.
The appliance will be connected to a combined flue gas discharge / combustion air supply system, hereafter to be
referred to as the concentric system.
The passage to the outside can be made with both a wall terminal and roof terminal. If necessary, you can also use
an existing chimney (see section 5.8.4).
!Caution
Only use the concentric system supplied by DRU This system has been tested in combination with the
appliance. DRU cannot guarantee a proper and safe operation of other systems and does not accept any
responsibility or liability for this;
For connecting to an existing chimney you should only use the chimney kit supplied by DRU.
The concentric system is constructed from (the flue spigot of) the appliance.
If, due to constructional circumstances, the concentric system is placed first, it is possible to connect the appliance
by means of a telescopic pipe piece.
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Diablo Next at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Diablo Next in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Diablo Next

DRU Diablo Next User Manual - English - 20 pages

DRU Diablo Next Installation Guide - German - 36 pages

DRU Diablo Next User Manual - German - 20 pages

DRU Diablo Next Installation Guide - Dutch - 36 pages

DRU Diablo Next User Manual - Dutch - 20 pages

DRU Diablo Next User Manual - Dutch - 16 pages

DRU Diablo Next User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info