7
If after checking all the above points, the refrigerator is still
not working satisfactorily, contact your nearest service
engineer. State the problem, model, product- and serial-
number.
(Details of the model, product- and serialnumber are to be
found on the data label in the top left of the inside
compartment.)
This refrigerator is equipped with overheating protection. An
authorised service technician can check whether this has
been triggered or not.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
13. Putting into operation
Technical data:
13.1. Connecting to electrical mains
The appliance may only be operated from nominal
voltage mains as shown on the data plate. The
appliance mains plug may be connected to a mains socket
earthed in accordance with regulations.
Any electrical work required to install this appliance should
be carried out by a qualified electrician or competent
person.
The manufacturer declines any liability should these
safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance rating
plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In the
event of having to change the fuse in the plug supplied, a 3
amp ASTA approved (BS 1362) fuse must be used. Should
the plug need to be replaced for any reason, the wires in
the mains lead are coloured in accordance with the
following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured green and yellow must be connected
to the terminal marked with the letter „E“ or by the earth
symbol or coloured green and yellow.
The wire coloured blue must be connected to the
terminal „N“ or coloured black.
The wire coloured brown must be connected to the
terminal marked „L“ or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
14. Environmental protection
information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound) is
used as a refrigerating agent in the refrigeration unit.
The ozone-friendly cyclopentane is activated as a motive
agent for the PU foam insulation.
Sodium chromate is used for corrosion protection (less
than 2 weight % of the coolant).
15. Recycling
After unpacking the appliance, the packing materials
should be delivered to a local collection site. At the end
of its useful lifetime, the appliance should be delivered to
a specialised collection and reprocessing firm, which
reclaims the usable materials. The rest is properly
destroyed.
Appliances bearing this symbol must be
deposited at the designated local reception
point for the disposal of electrical and
electronic equipment.
It is not permitted that this product be
disposed of by way of the normal household
refuse collection system.
Dometic refrigerators bear this symbol on the
specifications plate (data plate) to be found in the interior
of the unit.
This appliance compiles whit the following EEC
directives:
LVD-Directive 2006/95/EC
EMC-Directive 2004/108/EC
CE-Directive 93/68/EEC
RoHS-Directive 2002/95/EC
WEEE-Directive 2002/96/EC
GB
Model DS301H DS601H
Type DSH20-60 DSH20-60
Gross volume 28,1 litre 52,6 litre
Mains operation 220 - 240V (AC) 220 - 240V (AC)
Input 65W 85W
Energy consumption 0.86 kWh/24h 1.05 kWh/24h
Climate class SN SN
Refrigerant 151g H
2
O + 101g NH
3
157g H
2
O + 105g NH
3