798170
44
Zoom out
Zoom in
Previous page
1/52
Next page
EN-18 2007/A www.dimplex.eu
English Electrical connection
Circuit diagram
A1+, A2- DC signal charge control
A1~, A2~ AC signal charge control
Ex RT External room thermostat (optional)
K1 Heater contactor
L1, L2, L3 Phase
LE Fan control
LER Controller charge, discharge
LH Supplementary heating control
L-R Phase controller
L-SH Phase direct control
M1 Fan
N Neutral conductor
N-R Neutral conductor controller
21
230V ED%
0,91...1,43V DC
A1/Z1~
A2/Z2~
A2-
A1+
N
L-SH
2
3
4
5
6
7
N
K1
N-SH
N
L3
L2
L1
L3
L2
L1
R3
R2
R1
PE
PE
1
8
9
N-R
12
13
14
15
16
17
11
18
PTC
STR
M1
L-R
NL
N
LH
LE
N
L
LER
UI
NTC
A2-
A1+
N-SH
L-SH
A2~
A1~
N
REL 1
LE
N
L
N
TRG
TR9*
R9*
R7
Ex RT
REL 2
REL 4
REL 3
REL 5 TB
N-SH Neutral conductor direct control
NTC Residual heat sensor (core)
PE Protective conductor
PTC Room temperature sensor
REL 1 - 5 Relay 1 - 5 (controller)
R1-R3 Heating elements
R7 Series resistor
R9 Supplementary heating (optional)
STR Safety thermo controller
TB Safety temperature limiter
TR9 Supplementary heating thermo controller
TRG Ventilation grid thermo controller
UI Operating panel, display
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex VFE50K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex VFE50K in the language / languages: English, German as an attachment in your email.

The manual is 4.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info