!Tip
When replacing the glass pane always replace the glass pane seal in the door (= seal between the glass pane and
the door) AND the door seal (= seal between the door and the fire).
9.4.1.2 Disassembly of side panes
The side panes must be replaced in case of cracks or fractures in the glass pane.
Ø
Unscrew the Allen screw (see Annex 2, fig. 11).
Ø
Now follow the steps described in paragraph 9.4.1.1 ‘Disassembly of glass pane in door’.
!Caution
The side panes are made of IR glass. This glass consists of a coating that reflects a large part of the infra red
radiation (heat radiation). This glass is characterized by a rough (coating) and smooth side. It is very important that
the side panes are mounted with the coated side towards the outside.
!Tip
Mark the coated side of the side panes before disassembling the side pane. This will help you to place back the
side panes correctly.
9.4.2 Assembly of glass panes
9.4.2.1 Assembly of glass pane in door
Assemble the glass pane in the door according to the steps described in paragraph 9.4.1.1 ‘Disassembly of glass
pane in door’, only in reverse order.
!Caution
- Do not fasten the bolts too tight to avoid breaking off and/or stripping: overtightening will cause breakage.
- Place the glass pane (including new pane seal) with the logo to the bottom right.
- Place a new door seal.
- Slide both ends of the door seal in the supplied sleeve (see Annex 2, fig. 10).
!Caution
Make sure that the sleeve is placed on the underside of the glass pane.
9.4.2.2 Assembly of side panes
For assembly of the side panes, please observe the instructions provided in paragraph 9.4.1.2 ‘Disassembly of side
panes’, only in reverse order.
!Caution
Properly press down the side doors during assembly, before the Allen screws are tightened again! The side doors
must fit onto the appliance properly, in order to prevent leakage and attraction of false air.
!Caution
Mount the panes with the rough (coated) side towards the outside (see 9.4.1.2).
9.5 Supplementary installation instructions per appliance
9.5.1 Vidar Wall
9.5.1.1 Placing the appliance
This appliance should be installed as suspending from a wall.
!CAUTION
The Vidar Wall should only be mounted to a vertical wall made of solid, non-combustible and heat resistant
material.
!Caution
The flue exhaust (niche pipe or connecting piece suitable for stainless steel pipe 150 mm) in the ceiling should be
190 mm from the wall, measured from its centre. In all other cases, you must use bends.
When placing the fire, please proceed as follows (see Annex 2, fig. 12):
Ø
Mount the wall plate. The recommended height is 930 mm (A), measured from the top of the wall bracket
(= 450 mm (B) from the bottom of the appliance to the floor)).
!Caution
When attaching the wall plate, maintain aminimumheight of 780 mm (A) (= 300 mm (B) from the bottom of the
appliance to the floor))!
Ø
Attach the wall plate with the supplied key sleeves and key bolts. Make sure everything is mounted level and that
the wall plate is centrally located under the flue exhaust in the ceiling.
UK
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dik Geurts Vidar Triple-wall at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dik Geurts Vidar Triple-wall in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dik Geurts Vidar Triple-wall

Dik Geurts Vidar Triple-wall User Manual - English, German, Dutch, French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info