INSTALLATION MANUAL
9.2.2 Connection of the flue
9.2.2.1 Regular connection of the flue
In an existing situation the flue can be connected in 3 ways: without venting material, using a fixed connection or
by using a flexible connection.
!CAUTION
Not all connection methods are allowed in all countries! Install the appliance strictly according to the
country-specific conditions.
For the method without venting material you must create an airtight connection with ceramic wool between
the top side of the fire and the chimney (see paragraph 5.7.2).
When making a fixed connection use must be made of the specially developed tapered ring or the draining
flex/fix connecting piece. This is available through your supplier.
Proceed as follows (see Appendix 2, Fig. 5a to 5c):
Ø
Fix the ring/connecting piece using 3 bolts on the top side of the appliance.
Ø
Fit the appliance.
Ø
Slide the pipe over the tapered ring or into the draining flex/fix connecting piece.
A draining flex/fix connecting piece is available for a flexible connection.
Proceed as follows (see Appendix 2, Fig. 5a to 5c):
Ø
Pull the flexible pipe through the chimney.
Ø
Fix the draining flex/fix connecting piece using 3 self-tapping screws to the flexible pipe.
Ø
Push the flexible pipe including connecting piece back in the chimney.
Ø
Slide the fire into place.
Ø
Remove the flame baffle plate(s) if this is/these are already in the correct place in the top of the appliance
(see paragraph 9.7.1.3.2 (Instyle en Prostyle 700) or 9.7.2.3.2 (Instyle en Prostyle 700).
Ø
Insert a hand through the flue hole and grasp the connecting piece handle.
Ø
Pull the flexible pipe with the connecting piece downwards.
Ø
Fasten the flexible connecting piece to the appliance with 3 bolts.
!Caution
The handle in the flexible connecting piece (see Appendix 2, Fig. 5b) can be broken out after installation. This is
not necessary but can be desirable for sweeping the chimney.
Tip!
The draining flex/fix connecting piece can be used to make both a flexible or fixed connection.
!Caution
With a fixed connection the pipe material lowers fully into the connecting piece, with a flexible connection only
half of it (see Appendix 2, Fig. 5c).
9.3 Door(s) adjustment
Check the closing of the door(s) with installation or maintenance. The door(s) can be adjusted if desired. This is the
case if sealing is insufficient is (gaps).
Ø
Check the sealing of the door by placing a sheet of paper between the door and the fire. After closing the door the
sheet of paper may not be able to be easily pulled out. Check around the door.
Proceed as follows when adjusting the door:
!Caution
When you install an Instyle or Prostyle Tunnel: Follow the instructions below. Then repeat these instructions on
the other side of the appliance.
Ø
Loosen the 2 hexagonal bolts on the top and bottom side of the hinging part of the door with an open-end
spanner one turn (see Appendix 2, Fig. 6).
!Caution
Do not fully remove these bolts!
Ø
The door can now be adjusted.
Ø
Check whether the door still seals well using the test with a sheet of paper described above.
Ø
Tighten the bolts again.
In case the door(s) still doesn't(don't) seal properly:
Ø
Replace the sealing cord (see Appendix 2, Fig. 7).
Ø
Adjust the door handle.
40
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dik Geurts Instyle 800V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dik Geurts Instyle 800V in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dik Geurts Instyle 800V

Dik Geurts Instyle 800V User Manual - English, German, Dutch, French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info