2 Placing and installation of sensors
2.2 Installing ground sensors
At this point you must have located the appropriate spots for the ground sensors and extended
the feeder cable if necessary as prescribed in section 2.1.
The sensor part and the sensor tube may now be installed in connection with the actual con-
struction work and connected at a later date. The following applies for all types of installations.
a) The base below the sensor tube must be hard, e.g. a concrete plate or similar, in order to
ensure that the sensor is not pushed into the ground if e.g. a lorry runs over it. The tube is
designed to be mounted on a plate using the two screw holes inside the tube.
b) Place the sensor tube in between the heating cables with a minimum distance of 1 cm.
c) The sensor tube must be positioned so that it is flush with the surrounding
terrain and so that the sensor part must be placed so that the upper brass
surface is horizontal.
d) Lay a conduit for the sensor cable between the
sensor tube and the Devireg 850 controller.
illustration 6.1.1.3
installation pipe
illustration 2
illustration_a_b_c
min. 1 cm
min. 1 m
Assembly box
Feeder cable
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Devi DEVIreg 850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Devi DEVIreg 850 in the language / languages: English as an attachment in your email.

The manual is 0.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Devi DEVIreg 850

Devi DEVIreg 850 User Manual - English - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info