Before installation
Connecting to Ø150 mm exhaustair duct
Attach the enlarging adapter (enclosed or
available from specialist dealer) to the air
outlet. Attach the exhaust-air duct to the
adapter.
If a backflow flap has been installed, check
that it functions properly.
Circulating-air mode
With activated carbon filter if exhaust-air
mode is not possible.
The air purified by an additional activat-
ed carbon filter is returned to the room.
After installing the extractor hood, insert
the activated carbon filter.
For installing see Filters and maintenance.
If the extractor hood is installed beneath a
cabinet, ensure that there is an adequate air
outlet (min. 177 cm
2
).
The extractor comes as standard equip-
ped with a protective grid in the air connec-
tor. If this is has been removed (in the case
of exhaust air operation), the air connector
must be supplemented by a reducer piece
with protective grid (see section on special
accessories).
WARNING:
THIS APPLIANCE MUST BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the power cord are colourcod-
ed as follows:
Green and Yellow – Earth
Blue Neutral
Brown – Live
If you fit your own plug, the colours of these
wires may not correspond with the identify-
ing marks on the plug terminals.
Proceed as follows:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or coloured
green or green and yellow.
2. Connect the blue (Neutral) wire to the ter-
minal in the plug marked ‘N’ or coloured
black.
3. Connect the brown (Live) wire to the ter-
minal marked ‘L’, or coloured red.
The extractor hood may be connected
to a correctly installed earthed socket only.
Attach the earthed socket near the extrac-
tor hood in an accessible position.
q The earthed socket should be connec-
ted via its own power circuit.
If appliances do not feature the OFF
delay function, the indicator may start flas-
hing when the extractor hood has been
switched off for several hours via a separate
switch, even though the grease filters are
not yet saturated.
(See Filters and maintenance).
Electrical specifications:
These can be found on the rating plate
inside the appliance following removal of
the filter frames.
Before carrying out repairs, always
isolate the appliance.
Length of the connection cable: 1.30 m.
If permanent connection is required:
The extractor hood may only be con nected
by an electrician registered with the local
electricity board.
A disconnecting device must be provided
on the installation side. Switches with a
contact opening of more than 3 mm and
all-pole disconnection are regarded as dis-
connecting devices. These include LS
switches and contactors.
If the connecting cable for this applian-
ce is damaged, the cable must be replaced
by the manufacturer or his customer service
or a similarly qualified person in order to
prevent serious injury to the user.
This extractor hood complies with EU regu-
lations on interference suppression.
Electrical connection Installation
Please note: A wall hanging set can be
obtained from your dealer (see section on
special accessories) for fastening the hood
(e.g. at the end of the row of kitchen units).
The extractor hood is designed for
installation between two wall cabinets.
1. Remove grease filter
(see Filters and maintenance)
2. Using the enclosed template mark the
positions of the screws on the side pan-
els of the neighbouring cabinets.
The extractor hood can also be installed
slightly lower, depending on the height of
the wall cupboards. Position the template
correspondingly lower.
Observe the minimum distance from hob to
extractor hood of
650 mm (the fixing
screws
must be fitted at least 1040 mm
above the hob
).
3. Predrill (with bradawl or 2 mm bit) and
screw in the screws to 5 mm.
4. Suspend the extractor hood on the two
screws between the wall cabinets.
5. The two door carriers of the extractor
flap must be pushed into the appliance
to he stops.
6. Align the extractor
hood with the lea-
ding edge of the
side cabinets.
34
34
20
20
5 mm
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Constructa CD22130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Constructa CD22130 in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 9,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info