652338
73
Zoom out
Zoom in
Previous page
1/80
Next page
73Fault elimination
Code Message Information
Warning Fault Possible causes Remedy
––– E95 No Heating voltage Heating voltage missing although a demand is present.
Note: As soon as the heating voltage is present again, the Condair RS continu-
ous normal operation.
Main contactor defective. Let have the main contactor be checked/
replaced by an electrician
Phase failure heating voltage supply. Check/switch on electrical isolator in the
mains supply line. Let have fuses in the
mains supply line be checked/replaced
by an electrician.
––– E97 ** Ext. 24V Supply External 24 V supply faulty. Voltage too high or too low.
Fuse "F2" on the driver board defec-
tive.
Replace fuse "F2" on the driver board.
Short circuit on external connection. Remedy short circuit.
Overload on external connection. Disconnect load on terminal X16.
––– E98 ** Ext. 10V Supply External 10 V supply faulty. Voltage too high or too low.
Fuse "F2" on the driver board defec-
tive.
Replace fuse "F2" on the driver board.
Short circuit on external connection. Remedy short circuit.
Overload on external connection. Disconnect load on terminal X16.
––– E100 ** IO Inlet 1 Fault on inlet valve 1.
Valve electrically not connected or coil
defective.
Correctly connect valve or replace coil .
––– E101 ** IO Inlet 2 Fault on inlet valve 2 (only on units with increased control accuracy).
Valve electrically not connected or coil
defective.
Correctly connect valve or replace coil .
––– E111 ** IO Drain 1 Fault on the optional drain water cooling valve.
Valve electrically not connected or coil
defective.
Correctly connect valve or replace coil .
––– E112 ** IO Drain 2 Fault on the optional drain valve of the scale collector tank.
Valve electrically not connected or coil
defective.
Correctly connect valve or replace coil .
W120 E120 ** Fill time min. If the minmum ll time is underrun the Condair RS carries out a level test. This
procedure is repeated three times if minmum ll time is underrun again, then a
fault message is triggered and humidication is stopped!
Level unit is scaled. Clean level unit.
Hose connections from the level unit
to the steam cylinder are clogged.
Check hose connections from the
level unit to the steam cylinder and
clean if necessary.
W121 E121 **
Max.vaporization
time
If the maximum vaporization time is exceeded the Condair RS carries out a level
test. This procedure is repeated three times if maximum vaporization time is
exceeded again, then a fault message is triggered and humidication is stopped!
Individual heating elements faulty. Replace faulty heating elements.
Fuses on the power board defective. Let have fuses on the power board be
replaced by an electrician.
Mains voltage too low or failure of a
phase (L1, L2 or L3).
Let have the mains voltage and con-
nections be checked by an electrician.
Steam lead too long or not insulated. Maintain maximum steam line lengths
(max. 4 m), Insulate steam line.
This error may also occur upon a cold
start
Enable Soft start function.
E124, E200,
E201, E210
––– See malfunction list in the Condair RO-A installation and operation manual.
––– E300 Blower security
contact open
Enable contact of the blower pack open.
No voltage supply to blower pack pre-
sent.
Check/correctly connect cabling to
blower pack.
Operation without blower pack: jumper
wire "J1" not connected to terminal block
"X12" on driver board.
Connect jumper wire "J1" to terminal
block "X12" on driver board.
** These fault messages must be reset by switching the Condair RS off and on again (see chapter 7.5)
73


Need help? Post your question in this forum.

Forumrules
1

Forum

condair-rs

Reset search

  • why drain hose led to left, is it due to electrical on right side.
    Submitted on 29-8-2022 at 23:32

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair RS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair RS in the language / languages: English as an attachment in your email.

The manual is 5,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair RS

Condair RS Installation Guide - English - 80 pages

Condair RS User Manual - Dutch - 80 pages

Condair RS Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info