3.3 Setting switching sensitivity
According to factory default settings, the switching sensitivity is
±0.2°C (the display indicates this setting with symbol S:1”) which
can be modified to +0/-0.2°C (the display indicates this setting with
symbol S:2”). The required switching sensitivity can be set by
pressing DAY”, “COPYand the large or buttons one after
the other, after going back to the main screen by pressing the “SET
button. Setting S:1 (±0.2°C switching sensitivity) or S:2(+0/-0
.2°C switching sensitivity) is acknowledged by pressing the “SET”
button. (After approximately 10 seconds, the settings are automati-
cally acknowledged and the device goes back to the main screen).
Pressing the RESET” button the switching sensitivity is reset to fac-
tory default setting, i.e. to ±0.2°C level (“S:1”).
The ±0.2°C switching sensitivity ensured by factory default
settings (the display shows symbol “S:1” for this setting) is primarily
recommended for radiator-based central heating systems (e.g.
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Computherm Q7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Computherm Q7 in the language / languages: English as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info