TECHNICAL DATA
— switchable current: 8A (2A inductive load)
— temperature measurement range: 0 to 35°C (in 0.1°C increments)
— adjustable temperature range: 7 to 35°C (in 0.5°C increments)
— temperature measurement accuracy: ±0.5°C
— selectable switching sensitivity: ±0.2°C (for radiator-based heating systems)
+0/-0.2°C (for underfloor heating)
— storage temperature: -10°C to +60°C
— power supply voltage: 2x1.5V AA alkaline batteries (LR6 type)
— power consumption: 1.3mW
— battery lifetime: approx. 1 year
— dimensions: 130 x 80 x 35mm
— weight: 154 g
— temperature sensor type: NTC 10Kohm ±1% at 25°C
31