1.8 Ordering replacement parts
For the end-user: Contact the service centre and/or your dealer to request any replacement parts.
For the dealer: To request any replacement parts contact the Cola s.r.l. service centre and/or send a fax clearly
specifying the following data:
- stove model;
- serial number;
- date of purchase;
- list of replacement parts;
- details of faults encountered.
- Operations on parts must be carried out by authorised and/or qualified personnel.
- Only use original Cola replacement parts.
1.9 Stove decommissioning
For disposal, the stove must be sealed inside strong packing; contact the local authority in charge of such
operations in order to proceed according to the current local regulations.
2 – TRANSPORT AND INSTALLATION
2.1 Packing, handling, shipment and transport
The stove can be lifted using a lift truck, inserting the forks (of suitable length) in the special spaces in the
wooden packing.
Make sure the equipment used for lifting and transport can take the weight of the stove, specified on the
dataplate and in this manual.
Avoid taking the load in areas where it could be a danger if dropped.
Set the stove down on the floor carefully without bumping, and position it in the required place; make sure the
floor can take the weight of the stove, otherwise consult a specialised technician.
2.2 Instructions for safe installation
The stove must be installed by a technician, taking into account the local, national and European regulations.
The unit must be placed on a floor able to take its weight; otherwise corrective measures can be taken
according to the advice of specialised technicians. Flammable parts or those sensitive to heat must not be kept
near the glass, as this zone becomes hot. The minimum front distance for the protection of flammable objects is
80 cm. The minimum side distance and that of the rear wall from flammable parts or those sensitive to heat is
20 cm. If the support base is made of flammable material (wood, cork, etc.) a protection base in 2-3 mm thick
steel plate or a sheet of toughened glass must be provided.
2.3 Connection to the flue
The MARY stove must be connected to the flue with connection supports located at the top of the stove body
and by means of flue pipes readily available on the market. Connection to the chimney must be made using
strong and stable pipes, with recommended minimum thickness of 1.2-2 mm. The flue pipe must possibly be
straight, to avoid pressure losses, and towards the flue. The individual parts of the flue pipe must be sealed.
To ensure regular operation, the flue draught with stove operating must be between 10 and 14 Pa.
For optimum stove efficiency, a draught control or
damper must be fitted in the
flue pipe or chimney.
Every unit must eliminate the fumes through its own flue; never use the same flue for several units.
2.4 Room ventilation
The air necessary for combustion, i.e. up to 20 m³ every hour, must be ensured in rooms where stoves with
natural flue draught are installed. The air change must occur through several fixed openings to the outside,
whose cross section must comply with the current local regulations. Such openings must be protected with
grilles and must never be obstructed.
If the air is insufficient, even the operation of an extractor hood in the room or exhaust fans can negatively affect
stove operation.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Mary at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Mary in the language / languages: English as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info