Bea
Roof
angle
(α)
Distance
B
H
15°
0,50
m
30°
0,50
m
45°
0,50
m
60°
Less than 1.85 m
0,50
m
Min
0.5m
Approx.
0.5m
Min
0.5m
Min
0.5m
The
chimney
mouth
must
be
at
least
0.5m
from
the
top
of
any
obstacle
within
a
range
of
10
m
obstacle
Less
than
5
m
fig
2
Chimney
pot
distances
and
positioning
UNI
10683/98 tables
Roof
angle
(α)
Distance
A
H
15°
1,00
m
30°
1,30
m
45°
2,00
m
60°
Greater than 1.85 m
2,60
m
Before
installing
a
stove
to
an
old
flue,
besides
observing
what
has
already
been
described,
it
will
be
necessary
to
check
there
are
no
openings
or
cracks
through
which
air
can
pass
that
would
decrease
the
temperature
and
impair
the
idraught.
Lastly,
check
there
are
no
obstructions
caused
by
foreign
bodies
or
soot
deposits
accumulated
over
years
of
operation.
It
is
advisable
for
the
first
coupling
section
leaving
the
kitchen
to
be
vertical,
while
the
flue
fitting
entering
the
chimney
that
leads
to
the
chimney
pot
must
be
inserted
by
a
few
centrimetres
so
as
not
to
decrease
the
cross-
section
of
the
flue.
If
the
flue
is
not
perpendicular
to
the
axis
of
the
chimney
it
is
advisable
to
make
the
NO
connection
with
special
steel
fittings
that
permit
a
maximum
tilt
of
45°.
In
the
case
of
walls
and
ceilings
made
of
flammable
materials
it
necessary
to
MAX
45°
YES
NO
Fig. 3 Stove-chimney connection
insulate
the
portion
in
contact
with
the
flue
appropriately.
In
addition,
it
is
necessary
to
carefully
seal
the
fittings
at
the
coupling
points
especially
where
the
fitting
enters
the
flue.
If
there
is
more
than
one
range
in
the
same
dwelling,
each
one
must
have
its
own
flue.
It
is
not
recommended
to
make
any
openings
in
the
flue
to
apply
other
appliances
since
the
draught
could
be
impaired.
According
to
the
UNI
7429
standard,
the
chimney
must
respect
certain
requirements;
firstly,
it
must
have
a
useful
outlet
cross-section
of
at
least
twice
the
cross-section
of
the
flue.
In
addition,
it
is
preferable
to
install
a
“anti-wind”
chimney
pot
fitted
with
winged
profiles
that
ensure
fume
exhaust
even
when
there
are
strong
horizontal
winds.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Bea at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Bea in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info