EN
Fig. 2 EWH water connection diagram
EWH
Protective
cover
Flexible hoses
Cold water main
Hot water main
Safety valve
Drainage in the sewers
Flexible hoses
Hot water faucet Cold water faucet
Cold water shut off valve
to points of
consumption
Hot water shut off valve (close
when operating EWH)
7.3.
Possible faults and remedies.
Malfunction
Possible cause How to fix
Hot water pressure from
Clogged inlet safety valve Remove the valve and clean it in
water
Heating time increased THE is covered with a layer of
sludge
Remove the flange and clean the
TEH
Supply voltage decreased
Contact power main
operation service
Powered EWH does not
heat water. No
backlights of indicator
lamps
Thermal switch
tripped.
Wait for safety thermal switch to
lower water temperature in the
tank
Frequent tripping of
thermal switch
The set temperature is close to
the limit
Turn the thermostat control to
decrease temperature (-)
Thermostat tube is covered with
sludge
Remove the flange and gently clean
the pipe from the sludge
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cointra Thermex Blitz IBL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cointra Thermex Blitz IBL in the language / languages: English as an attachment in your email.

The manual is 0,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info