684041
68
Zoom out
Zoom in
Previous page
1/80
Next page
68
Unit component What to clean and how to clean
Drain cup Use a brush to remove any limscale from the drain cup
and the receptacle on the bottom side of the unit (do
not use a wire brush).
If the drain cup is heavily calcied, place it in an 8% formic
acid solution (observe safety notes in chapter 7.5),
until the limescale comes off.
Wash the drain cup and the receptacle on the bottom
side of the unit with a lukewarm soap solution, rinse the
parts well with tap water.
Interior of the unit
(water side only)
Wipe the interior of the unit with a damp cloth without using
any cleaning agent.
CAUTION: Take care that the electrical connections and
the electronic components remain dry!
7.5 Notes on cleaning agents
Only use cleaning agents stated in the table above. The use of
disinfectants is only permitted if they do not leave any toxic residues. In
any case the parts must be thoroughly rinsed with water after cleaning.
WARNING!
Formic acid is indeed harmless to the skin, but it attacks the mucous
membranes. Therefore prevent your eyes and respiratory tracts from
getting in touch with the acid and its vapours (wear goggles and work in
a well ventilated room or outside).
CAUTION!
Do not use any solvents, aromatized or halogenized hydrocarbons
or other aggressive substances as they may cause damage to the
components of the unit.
It is mandatory to observe and comply with the information and instructions
regarding cleaning agents. Observe in particular: all information relating
to the protection of personnel, environmental protection and restrictions
regarding usage.
7.6 Resetting the maintenance indication
After completing maintenance work, the maintenance indication (yellow
LED lights) must be reset as follows:
Press drain key with the unit switched off and hold down.
Switch on steam humidifier via the unit switch.
Hold drain key down until the system test is completed (approx. 10
seconds).
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cleopatra Cleo Eco Pro Steam generator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cleopatra Cleo Eco Pro Steam generator in the language / languages: English as an attachment in your email.

The manual is 10,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info