588931
24
Zoom out
Zoom in
Previous page
1/38
Next page
24
7. Functions
In this chapter all possible indications are explained.
Whether these indications really appear, depends on whether or not they are switched on in the mo-
mentary current profile.
Some functions only appear in the altimeter mode , some only in the barometer mode .
This is indicated through an appropriate symbol in the single functions.
The functions in the upper display (chapter 5.1) can be called up with the
UR-button, the correspon-
ding sub-functions of the particular functions can be called up with the
UL-button.
The functions in the lower display (chapter 5.3) can be called up with the LR-button, the corresponding
sub-functions of the particular functions can be called up with the LL-button.
The functions in the medium display (chapter 5.2) can be called up by short pressing of the
MR-button.
There are no sub-functions of these functions.
Important: In order that the HAC5 calculates and displays all values (and saves them for the PC eva-
luation), a recording needs to be started (see also chapter 8.1). This happens by simultaneous pressing
of both left buttons for 3 seconds (the present profile is indicated in the display for 10 seconds and the
”-symbol flashes on top of the display as a sign for a running recording).
To stop the recording (at the end of the training) press both left buttons again simultaneously for
3 seconds (“
” stops flashing).
All minimum, maximum and average values (display indication: MIN/MA/AV) and also all daily values
(DAY) are only calculated when a recording was started.
This means: when the recording is not started during a training, the values of the last saved tour are
indicated in the above-mentioned displays, not of the present tour.
The sub-functions shift back automatically into the normal operational mode after 10 seconds.
7.1 Function indications of the upper display
Heartrate
Indicates the current heart rate.
Range: 20 – 250 bpm (beats per minute)
Note: The HAC5 can only indicate a heart rate when the appropriate transmitter belt is worn and this
function for the current program is switched on. The heart rate functions have a powerdown-mode:
when there is no impulse for approx. 10 minutes, the heart rate receiver (of the HAC5) switches off
automatically (instead of the HF indication in the text line the indication “HR: no TX” appears).
The heart rate receiver only restarts after a new transmitter search (e.g. by starting of a recording or by
a new selection of the function “current heart rate this function has to appear in the display for at
least 5 seconds).
Average heart rate
Sub-function of the current heart rate function.
IIndicates the calculated average heart rate in the upper display since the beginning of the present tour.
Range: 20 – 250 bpm
In the lower display the average heart rate of the personal maximum heart rate is indicated in per-
centage.
Range: 0 – 100%
Maximum heart rate
Sub-function of the current heart rate function.
Indicates the maximal reached heart rate during the recording in the upper display.
Range: 20 – 250 bpm
In the lower display the maximum heart rate of the personal maximum heart rate is indicated in per-
centage.
Range: 0 – 100%
Recovery heart rate
Sub-function of the current heart rate function.
Indicates the recovery heart rate (see also chapter 8.3).
The heart rate, which was measured at the beginning of this function, appears in the upper display. The
recovery heart rate, which was measured after 3 minutes, appears in the lower display.
Range: 20 – 250 bpm
Average heart rate
Maximum heart rate
Recovery heart rate
Function indications
of the upper display
Heartrate
Alti Mode Baro Mode
Value
139
Ø-Heartr.
71.6
%Pers.Max.
Value
192
Max-Heartr.
99.0
%Pers.Max.
High
174
Recovery HR
86
Low
B
B
A
A
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ciclo HAC 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ciclo HAC 5 in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ciclo HAC 5

Ciclo HAC 5 Additional guide - English - 4 pages

Ciclo HAC 5 Additional guide - German - 4 pages

Ciclo HAC 5 Quick start guide - German - 2 pages

Ciclo HAC 5 User Manual - German - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info