IRIS Touch and Honeywell GT Dialler Installation Guide for LPS1277 compliance V1.3
June 2014
4
or IP router), together with Alarm Transmission Path (ATP) aerials* and
network access termination points, shall be located in an area provided with
‘direct alarm protection’
a)
.
ii) Other ‘Site Network Equipment’
b)
, for example intermediate junction boxes,
should be provided with ‘direct alarm protection’
a)
.
* Where an ATP aerial cannot be located in an area readily provided with ‘direct
alarm protection’
a)
and still achieve the recommended minimum signal strength
for adequate performance, it may be installed elsewhere (preferably indoors but
otherwise outdoors), subject to positioning it where its discovery and/or ready
access by intruders is considered unlikely.
3.1.3. Connections between the SPT and Site Network Equipment b)
i) Any radio based ATP shall have a cable connection between the SPT and
the required aerial, with all cable termination points, including those at any
intermediate connections, using termination components (or housings) that
protect against cable removal without the use of a tool.
ii) Any landline based ATP shall have a cable connection between the SPT
and the first suitable alarm transmission network termination point within the
premises. This shall be made in one continuous run and use termination
components (or housings) that protect against cable removal without the use
of a tool.
The connection to the alarm transmission network shall be made in such a
manner that where non-alarm related apparatus/services are also connected to
that network, they do not prevent, or interfere with, the correct operation of the
ATS.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chiron IRIS Touch - Dialler LPS 1277 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chiron IRIS Touch - Dialler LPS 1277 in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info