14 Woodtec Freestanding Issue 01.1 05/17
7.2 Warnings:
This appliance is not designed for open operation and therefore should not be operated with
the doors open.
This stove is designed to burn wood cleanly with high efficiency. However, for this product to
work properly it must be used correctly. If used correctly this stove will burn with the very
useful feature of clean glass.
It is essential that the stove has an adequate air supply for combustion and ventilation. DO NOT
block any ventilators provided. The primary, secondary and tertiary air inlets must be kept clear
of obstruction.
Warning! This appliance will be very hot when in operation and due care should be taken when
operating the controls. A tool and pair of quality leather gloves are provided to assist safe
operation.
Do not use an aerosol spray on or near the stove when it is alight.
7.3 The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the
authority to be a smoke control area. It is an offence to emit smoke from a chimney of a
building, from a furnace or from any fixed boiler if located in a designated smoke control area. It
is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it
is used in an "exempt" appliance ("exempted" from the controls which generally apply in the
smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in
accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of
the Deregulation Act 2015. Similarly in Scotland appliances are exempted by publication on a list
by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In
Northern Ireland appliances are exempted by publication on a list by the Department of
Agriculture, Environment and Rural Affairs under Section 16 of the Environmental Better
regulation Act (Northern Ireland) 2016. In Wales these are authorised by regulations made by
Welsh Ministers.
The Fireline Woodtec 5, 5 Wide and 5 Xtra Wide (5kW nominal outputs) stoves have been
recommended as suitable for use in smoke control areas when burning wood logs. This is
conditional upon fitting the supplied secondary air control limiters and following the wood
burning instructions precisely.
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules . Your local authority is responsible for
implementing the Clean Air Act 1993 including designation and supervision of smoke control
areas and you can contact them for details of Clean Air Act requirements.
15


Need help? Post your question in this forum.

Forumrules
1

Forum

charlton-jenrick-fireline-woodtec-5

Reset search

  • where will i locate the SERIAL No of my WOODTEC 5 wood burner for Warranty MANY THANKS Submitted on 17-5-2022 at 18:18

    Reply Report abuse
  • where will i find the SERIAL No on my WOODTEC 5 for the Warranty many thanks P. Loach Submitted on 17-5-2022 at 18:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charlton Jenrick Fireline Woodtec 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charlton Jenrick Fireline Woodtec 5 in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info