707656
16
Zoom out
Zoom in
Previous page
1/28
Next page
15 Woodtec Freestanding Issue 01.1 05/17
7.4 Air Controls
Keep air controls and inlets/outlets clean and free from ash or debris at all times. Keep direct
outside air inlet grille (if fitted) clean and clear at all times.
Do not leave air control fully open unless monitoring the fire as over firing damage can result
which is not covered by any warranty.
7.4.1 Single Air Control Operation
Secondary (air wash) and tertiary air is automatically controlled by the single control lever at the
bottom, underneath the stove door. The stove does not require Primary air as it only burns
wood. The fully IN position is the OFF position and closes off combustion air to the firebox. The
off position should only be used if absolutely necessary for very slow burning and will cause the
glass to become blackened, the chimney to gradually become tarred and smoke to be emitted
from the stove.
Wood burning: Pull the air control lever fully OUT for maximum air to start or revive a wood
fire. Returning the lever towards the centre position will reduce the air supply progressively to
reduce the burn rate. The nominal burn rate is usually achieved when the stove is fully warmed
up (2-3 loads of logs) and burning 2 dry hardwood logs by having the lever very approximately
30-35mm pushed IN from the fully out (maximum) position. This is only a rough guide as flue
and fuel conditions will vary the required position. The fire will automatically be supplied with
the correct mix of secondary and tertiary air for complete combustion. The maximum position
conveniently provides a boost of primary air as well to get new fuel burning quickly in order to
minimise smoke. Do not leave on maximum setting unless monitoring the fire to ensure over
firing damage does not occur.
7.4.2 Air Wash
All Fireline stoves are provided with a sophisticated “air wash” system to assist in keeping the
fire as visible as possible and reducing cleaning intervals. This secondary air supply to the stove
is controlled through the main single air control. The Clean Air Act air restrictor will deliberately
prevent full closure of this control on the Wood side of operation.
The glass will not remain fully clear indefinitely, entirely depending on fuel, flue and operational
settings, and will require cleaning with stove glass cleaner or ceramic hob cleaner from time to
time.
7.4.3 Tertiary Air
This appliance is also fitted with a patented tertiary air combustion system that burns otherwise
uncombusted gasses in the products of combustion thereby improving efficiency, increasing
heat output and decreasing unwanted atmospheric emissions. The Tertiary air supply to the
stove is controlled automatically by the draught in the flue and firebox and the single air control.
At certain stages of burning you will notice “jets” of swirling flame emerging near the air holes
to the rear of the firebox. This is not always visible depending upon the fuels and burn cycle
stage so there is nothing untoward happening if it cannot be seen.
16


Need help? Post your question in this forum.

Forumrules
1

Forum

charlton-jenrick-fireline-woodtec-5

Reset search

  • where will i locate the SERIAL No of my WOODTEC 5 wood burner for Warranty MANY THANKS Submitted on 17-5-2022 at 18:18

    Reply Report abuse
  • where will i find the SERIAL No on my WOODTEC 5 for the Warranty many thanks P. Loach Submitted on 17-5-2022 at 18:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charlton Jenrick Fireline Woodtec 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charlton Jenrick Fireline Woodtec 5 in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info