707656
13
Zoom out
Zoom in
Previous page
1/28
Next page
12 Woodtec Freestanding Issue 01.1 05/17
6.0 Technical Data & Declaration of Performance (DoP)
Manufacturer: Fireline UK, a Division of Charlton & Jenrick Ltd.
Range Designation: Woodtec freestanding stoves.
Models: Woodtec 5kW, 5kW Wide, 5kW Xtra Wide with nominal outputs of 5kW, 5kW and 5kW.
Intended Use: Domestic heating appliances
Independently Performance & Safety tested by: Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System: ISO9001
Signed:
Peter Mintoft
Director
April 2017
NOTE: Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are
comparative only. They do not relate directly to re-fuelling intervals that can be achieved on an installed product. Re-fuelling
intervals of 1-1.5h for wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal conditions on a
low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Model
Woodtec
5kW
Woodtec
5kW Wide
Woodtec 5kW
Xtra Wide
Notes
Appliance weight (packed/unpacked) (Kg):
75/66
89/78
96/85
Approximate Output Range: (kW)
3.5 -6.9
3.8 -7.0
3.7 - 8.0
Harmonised EN European Standard (hEN):
EN13240: 2001
Amd 2: 2004
EN13240: 2001
Amd 2: 2004
EN13240: 2001
Amd 2: 2004
Additional Characteristics Test Standard:
DIN +
DIN +
DIN +
Additional Particulate Emission Test Standard:
PD6434
PD6434
PD6434
Performance Characteristics Using Wood Fuel
Test Report Issue Date:
04/17
04/17
04/17
Total Efficiency: (%)
81.1
80.2
81.2
Declared nominal output: (kW)
5.0
5.0
5.0
Tested nominal Output: (kW)
5.0
5.1
5.0
Tested wood re-fuelling interval: (h)
0.8
0.76
0.79
Flue gas mass flow: (g/s)
3.9
4.3
4.1
Mean CO emission (@13% O
2
) : (%) (Nmg/m
3
)
0.08(1000)
0.1(1250)
0.1(1250)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
50
63
73
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
86
94
87
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
13
24
25
PD6434 Particulate Emissions High output: (gh
-1
)
1.9
1.7
2.6
PD6434 Particulate Emissions Low output: (gh
-1
)
1.8
1.2
1.6
Optical Density Time > 0.2 High (Mins)
0.5
0.2
0.4
Optical Density Time > 0.2 Low (Mins)
0.3
0.4
1.4
*Mean Flue Temperature: (Deg C)
272
270
254
Approximate Max Log Length: (mm)
300
400
450
Clearances from Combustible Materials
Side Wall: (mm)
400/450
550
500
Rear Wall: (mm)
300/150/100/75
300/175/125/75
250/200/150/100
13


Need help? Post your question in this forum.

Forumrules
1

Forum

charlton-jenrick-fireline-woodtec-5

Reset search

  • where will i locate the SERIAL No of my WOODTEC 5 wood burner for Warranty MANY THANKS Submitted on 17-5-2022 at 18:18

    Reply Report abuse
  • where will i find the SERIAL No on my WOODTEC 5 for the Warranty many thanks P. Loach Submitted on 17-5-2022 at 18:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charlton Jenrick Fireline Woodtec 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charlton Jenrick Fireline Woodtec 5 in the language / languages: English as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info