Troubleshooting
Technical and visual modifications as well as misprints reserved - © 2019 by ERGO-FIT GmbH & Co. KG
9 4
The displayed active blood pressure values are not plausible
Is the module defective?---> Carry out a metrological check
⊗ Resting blood pressure measurement issues.
---> Measuring active blood pressure is only possible when resting blood pressure
measurement is taken correctly.
Things to note when putting on the cuff during exercise.
---> The cuff tube must be carefully attached to the arm. An additional cuff strap
must also secure the tube at the forearm. The cuff tube should hang freely
and should not hit anything during the measurement process.
Instructions for the patient.
---> As soon as the patient recognizes that a blood pressure measurement
process is about to start, they must keep the arm relaxed, they should not
bend or stretch it too much, the cuff must not have any upper body contact.
The movement on the ergometer should be even and soft.
⊗ Methodological/basic error:
-tube fails during the measurement process,
-arm movement is too strong,
-other loud noise sources in the area --->
The cause of the noise must be looked into.
⊗ The cuff is attached incorrectly, the microphone is partly not touching the skin.
---> Put the cuff on properly (microphone must be completely in place, and it
must not protrude, otherwise it will pick up sounds in the room).
The displayed systolic values are too high when active
(At a cuff pressure above systole, the microphone picks up the noise and interprets it as
Korotkoff sound)
100


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cardiowise XRCISE Line at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cardiowise XRCISE Line in the language / languages: English as an attachment in your email.

The manual is 5,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cardiowise XRCISE Line

Cardiowise XRCISE Line User Manual - German - 148 pages

Cardiowise XRCISE Line User Manual - French - 144 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info