764872
6
Zoom out
Zoom in
Previous page
1/9
Next page
11
Part 6 : DRAIN & STORE
Drain System
Locate and remove the external threaded Drain Cap. Attach Drain Hose to Drain Outlet.
Locate and remove the stopper on the spa floor to allow water to drain.
Dry the Spa and Portable Control Unit
After a GFCI test, press the Jet Massage Button to blow out the water inside the jet holes.
Unplug the PCU, remove the filter cartridge from the Filter Housing and dry the PCU by draining
all water from PCU body and pipes. Open the Drain Valve on the bottom of the PCU, let the water
flow out and close the Drain Valve.
Storage
Use a towel to wipe off the spa and dry for 24 hours. Unscrew the Air Valve on both the
spa and the lid. Once the spa and lid has been deflated and the Foam Panels have been
disassembled, gently fold them for storage. It is recommended that you store the spa in its
original package in a warm dry place.
Part 7 PORTABLE CONTROL UNIT FUNCTION
A. Temperature Increase
Button
C. Blower/Jet
massage Button
B. Temperature Decrease
Button
D. Filter Button
E. Heat Button
G. Temperature Mode Button
F. LED Display
Functions of the Spa Portable Control Unit
LED Display: Once powered-up, the LED display will show the current water
temperature automatically.
‘Temperature Adjustment’ Buttons (A & B): Increase (A) Decrease (B). Pressing one
of the temperature adjustment buttons will cause the LED display to flash. When
it is flashing, you can set the desired temperature. The value will increase or decrease
by 1°F/ 1°C for each press. If you hold the button for 2 seconds, the values will
increase/decrease rapidly.
Temperature Adjustment Ranges: 86°F - 104°F/ 30°C - 39°C To lock the Portable
Control Unit, press (A) + (B) at the same time and hold them for 3 seconds. When the
spa is left unattended please be sure to lock the PCU to avoid having
the settings changed. Unlock the PCU by pressing (A) + (B) at same time
and holding for 3 seconds again.
‘Temperature Mode’ Button (G): Press this button to change from Celsius to Fahrenheit.
‘Jet Massage’ Button (C): Press this button to activate the Jet Massage system; when
activated a green indicator light turns on and ‘BUB’ is displayed on the screen. It can be
turned off by pressing it again.
NOTE:
The massage system will stop automatically after 15 minutes of operation. Re-activate
the jet function by pressing the jet button again.
When the filter mode is on, pressing the Jet Massage Button (C) will cause the filter
mode to turn off and the jet massage mode to turn on.
Heating and jet function can not be activated at same time. When heating system
is working, pressing (C) will change heating mode into jet mode: heating and filtering
are shut down, jet system is activated. If you press (C) again, heating and filtering
mode will re-start.
Pressing Filter Button (D) activates the filter system. This button turns the filter pump on
and off. The green indicator light will turn on when the filtration system is activated.
Note: When heating and filter functions are working at same time, pressing (D) will shut
down heating and filtering together. When (C) is on, filter and heating cannot be
activated, therefore (C) should be shut down first.
Pressing the Heat Button (E) activates the heating and filtering system at the same time
The green filter light and red heat light will be activated at the same time. The PCU
does not stop heating until the current water temperature reaches the set
temperature indicated by the ‘blinking’ red light.
When you press the Blower Button (C) the circulation pump and the heater will stop, as
a consequence the temperature on the display will decrease (due to no flow of water
between the PCU and the spa). To regain heating functionality turn the Blower Button (C
off and press the Heat Button (E). The circulation pump will restart and the temperature
will increase or the heating mode will restart automatically after the water temperature
drops 1°F/ 1°C (approx) below the set temperature. Max. heat temperature: 104°F (39°C).
Allow 24-48 hours to heat up your spa.
• This spa is equipped with automatic moisture protection which will activate the blower
of the PCU once a day for 90 seconds. This helps to prevent condensation build up and
increase the lifespan of the PCU.
Heater
Port
Blower Port
Air Valve
Filter Housing
Filter Port
Digital Display Pad
The Portable Control Unit
(PCU)
10
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Swift Current at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Swift Current in the language / languages: English as an attachment in your email.

The manual is 7,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Swift Current

Canadian Spa Company Swift Current User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info