764872
4
Zoom out
Zoom in
Previous page
1/9
Next page
1
www.canadianSpacompany.com
PORTABLE SPA
Swift Current
110-115V 60Hz 15 Amp
Read this manual before operation
www.canadianspacompany.com
Swift Current
Spa
PORTABLE
3
READ AND FOLLOW ALL SAFETY INSTRUCTIONS:
Basic safety precautions should always be followed when installing and using this electrical
equipment.
WARNING: The spa has been supplied with a residual operating current not exceeding 30 mA. The
GFCI must be tested before each use.
WARNING: No part of the appliance is to be located above the spa during use.
WARNING: This appliance is not intended for use by persons (including children) with reduced
physical, sensory, or mental capability.
WARNING: TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS RAINING.
WARNING: Children should be supervised at all times around the appliance.
WARNING: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent,
or similarly qualified persons in order to avoid a hazard.
WARNING: To reduce the risk of electric shock, do not use an extension cord to
connect unit to the electrical supply; use a properly located outlet.
WARNING: Make sure the home fixed connection box is more than 3.5m away from the spa.
WARNING: RISK OF ELECTRIC SHOCK. DO NOT BURY CORD. Ensure the electrical cord is
located away from lawn mowers, hedge trimmers, and other equipment. Reduce the risk of electric
shock by replacing damaged cords immediately.
WARNING: Electric installations should fulfil the requirements of local standards.
Appliance live parts, except parts supplied with safety-low voltage not exceeding 12 V, must be
inaccessible to a person in the spa.
WARNING: Parts incorporating electrical components, except remote control devices, must be
placed a safe distance away or fixed in position so that they cannot fall into the spa.
WARNING: Do not switch on if there is any possibility that the water in the spa is frozen.
DANGER: Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces.
DANGER: Risk of Electric Shock. Do not permit any electrical appliances, such as a light,
telephone, radio, or television, within 5 feet (1.5 m) of a spa.
DANGER: Risk of Accidental Drowning. Extreme caution must be exercised to prevent
unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless
they are supervised at all times.
DANGER: Never operate spa if the suction fittings are broken or missing. Never replace a suction
fitting.
CAUTION: Always consult your doctor before:
a) The use of alcohol, drugs, or medication, before or during spa use may lead to
unconsciousness with the possibility of drowning.
b) Obese persons and people with a history of heart disease, low or high blood pressure,
circulatory system problems, or diabetes, should consult a physician before using a spa.
c) Persons using medication should consult a physician before using a spa since some
medication may induce drowsiness, while other medication may affect heart rate, blood
pressure, and circulation.
d) Pregnant or possibly pregnant women should consult a doctor before using spa.
CAUTION: Wet areas around the spa can be slippery; always enter and exit the spa slowly
and cautiously.
CAUTION: In order to avoid a heater cut out and loss of operation, this appliance must
NOT be supplied through an external switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the utility.
CAUTION: Do not use the spa immediately following strenuous exercise.
CAUTION: Maintain water chemistry in accordance with the manufacturer’s instructions.
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS
Vinyl Warranty: Canadian Spa Co. warrants the
vinyl finish against defects in material and
workmanship and specifically against
blistering, cracking, or delamination, for the
period of one (1) year from the original purchase
date to the original purchaser. If Canadian Spa
Co. determines the vinyl to be defective during
this period, Canadian Spa Co. will repair or, at
its option, replace the defective spa liner/blad-
der without charge to the customer.
Plumbing Warranty: Canadian Spa Co.
warrants the plumbing of the spa will remain
free from leaks for the period of one (1) year
from the date of purchase to the original
purchaser.
Equipment Warranty: Canadian Spa Co.
warrants the equipment pack (pump, blower,
heater, and control system) against malfunction
and defects of the materials and workmanship
for one (1) year from the date of the purchase to
the original purchaser.
Extent of Warranty: This Limited Warranty
applies to portable spas manufactured after
October 1 2015 and sold by authorized
Canadian Spa Co. dealers to residential retail
customers. This Limited Warranty is given only
to the first retail purchaser and terminates upon
transfer of ownership.
No warranty is provided on filters or any dealer
installed accessories.
Cost of installation, removal, and/or shipping of
the spa, is not covered by this Limited
Warranty. In the event that Canadian Spa Co.
deems the removal of the spa to a place of
repair necessary or that the spa must be
replaced, any and all costs of the spa removal
and replacement (landscaping, decking, fenc-
ing and/or structure removal, alteration and/or
replacement; or other costs of providing access
to the spa) will be billed to the purchaser.
This Warranty applies only to spas in single
family, residential installations.
This Limited Warranty becomes void if the spa
is placed in commercial application.
Canadian Spa Co. Manufacturing extends the following warranties
to the original purchasers of its portable Spas:
2
5
Part 2 SPECIFICATIONS
Part 1 PACKAGE LIST
Swift Current Spa
Take all the spa components out of the box and
check your Instruction Manual that all the following key
components are present:
A) Foam Spa Walls x 8 (1 x Foam Panel with Connector holes,
1 x for Suction Line, 1 x Second Suction, 5 x Blank).
B) Thermal Blanket
C) Thermal Groundsheet
D) Spa Base/Liner (with integrated Portable Control
Unit Connectors)
E) Inflatable Cover/Lid
F) Spa Top Liner
G) Portable Control Unit (PCU) with GFCI plug
H) Inflation Hose
I) Drain Hose
J) Spare PCU Connector
K) Filters
L) Wallet includes: Instruction Manual,
Inlet/Outlet Caps x 3, Drain Stopper
Item:
Seating Capacity
Spa Dimension (inner)
Spa Dimension (outer)
Water Capacity
Voltage
Heater
Massage Jet Pump
Filter Pump
Max. Heat Temperature
Spa Lid Material
Liner
Net Weight
Gross Weight
Package Dimensions
Test Certificate (Pump only)
Heating Efficiency (Ambient temperature is 68°F /20°C℃)
CSCHTSC29
5 Persons
63’’ x 29” (160 x 74cm)
73” x 29” (184cm x 74cm)
1000L / 264 US gal
115V 60Hz
1340W
500W
30W
104°F (40°C)
Polyester Laminated PVC+Synthetic leather
Polyester Laminated PVC
105lbs / 48kg
115lbs / 52kg
#1:43”x 28.7”x29.5” / 109.5 x 73 x 75.5cm
#2: 25.8” x 21.4” x 22.8” / 65.5 x 54.5 x 58cm
CETL/ETL
1.5-2℃(°F) /hr
2
1
3
A
D
E
F
G
H
KL
I
J
B C
Part 3 INSTALLATION
1. Site Selection
IMPORTANT: Before you position, inflate, and fill with water follow these instructions:
1. Place in an area more than 8.2 sq ft (2.5 sq mtrs.)
2. Place spa on a surface that supports more than
100 lb/ft2 (488 kg/2).
3. The spa must be on a clean level ground. If placed
on uneven ground the weight of the spa water
may cause the spa to become distorted; this is not
covered by the manufacturer’s warranty.
Clean surface Level ground Ensure no kinked
connectors
Fill the tub up to
the water lines
on both interior
sides of the spa to
ensure the spa is
level.
Place Thermal
Ground Sheet
under spa
X
4
7
5) Align 2nd Intake Hose within the
existing slot in Foam Panel 2 (C). Begin
feeding Hose around the tub, through
Foam Panel 2, towards the Portable
Control Unit located on Foam Panel 1 (D).
7) Pull the Spa Top Liner down and align
with Spa Base Liner. Zip the two liners
together.
TIP: Ensure top and bottom zippers are
aligned before pulling the Top Liner down.
8) Smooth out wrinkles in the liner to the best of your ability and
pat out any pockets of air.
6) Attach the clear Intake Hose to the integrated Connection
Hoses. Place the clamp around the Intake Hose (fed through
exterior Foam Panels 1-3) and fasten the clamp with a flat-end
screw driver as close to the PCU as
possible. Ensure seal is water tight!
3. Spa Assembly
1) Take the Thermal Ground Sheet and
position it where the footprint of the
spa will be. Take the Spa Base Liner
and position it on top of the ground cloth.
2) Position Foam Panel 1 first and then add
Foam Panels 2 and 3 to the right of Panel
1. Ensure exact alignment between holes
in the foam and holes on the liner.
3) Place remaining blank Foam Panels
next to Foam Panel 3 until spa is
complete. Ensure the 3 holes in Foam
Panel 1 remain aligned with holes in the
Spa Base Liner.
TIP: Gripping the Foam Panel on both
sides and giving it a small
wiggle can help guide it in if it
gets stuck.
4. Connect the Portable Control Unit to the Spa
Position the PCU next to the spa, remove the Inflation Hose and align the Connection Hos-
es to the spa. Ensure that the hoses have ‘O’ ring gaskets inserted correctly (see fig. 1) at
each end. Please do not over tighten and check that the Connection Hoses are straight and
not kinked.
Fig 1. Ensure thicker part of
‘O’Ring Gasket faces inwards
4) Insert Spa Top Liner into the center of the
tub. Feed the integrated Connecton
Hoses and the Drain Hose through the
holes in Foam Panel 1 and the Spa
Base Liner (A). Loosen and remove clamp
that comes on 2nd Intake Hose
(B). Feed 2nd Intake Hose through the
hole in Foam Panel 3.
2. Test GFCI & Inflate Lid
a) Perform GFCI Test
WARNING: RISK OF ELECTRIC SHOCK. The GFCI plug must be
tested before each use. Do not use if GFCI test fails.
1. Insert the plug into the power outlet.
2. Press the “RESET“ button, the indicator light turns red.
3. Press the “TEST” button, the indicator light turns off.
4. Press the “RESET” button, the indicator light turns red; the pump is ready to use.
1 2 3 4
b) Inflate the Lid
Before the lid is inflated ensure the Valve Stopper (A) is fully pushed in to avoid air leaking
out. Connect the Inflation Hose to the Inflation Port on the PCU and then connect the
other end to the Inflation Port on the lid (B). Press the Massage Button (C) to inflate the lid.
Once inflated close the Valve Cap (D).
(A) (B)
(C) (D)
(A) (B) (C) (D)
6
9
Cleaning / Replacing Filter Cartridge
WARNING: RISK OF ELECTRIC SHOCK. Unplug the PCU
before beginning spa maintenance.
Note: A dirty filter cartridge may contaminate the spa water and
cause damage to the heating function.
1. Carefully thread the three plastic caps onto the inlet/outlet ports on inner spa wall.
(Ensure the rubber gaskets are in place within the plastic caps)
2. Unscrew filter housing lid by turning it counter-clockwise, then remove the filter
cartridge.
3. Rinse off filter cartridge with water and reuse if possible. Replace filter
if the cartridge remains dirty after rinsing or is badly discoloured.
4. Put the cleaned filter back into the cartridge housing and close the lid by
turning it clockwise.
5. Remove caps from inlet/outlet ports on inner spa wall and allow water to
flow into pump. Tub is now ready for use.
Part 5 WATER MAINTENANCE
5. Install the Filter Cartridge
Open the Filter Housing lid counter-clockwise. Put the new filter cartridge into the cartridge
chamber and close the lid clockwise. Ensure black “O” ring is placed correctly inside housing.
6. Pre-Fill Check
Ensure the drain outlet is extended for future draining/access (Fig. A), check that the washer is
in the cap, then tighten. Check the stopper (Fig. B) on the bottom of the spa and the Drain Cap,
ensure both are closed tight. Fill the spa with water using a garden hose until reaching the
water level printed on both interior sides of the spa wall (Fig. C1 & C2). These lines are also used
as an indication of the levelness of the spa. PCU must be connected to the spa prior to filling.
7. Purge Air From Portable Control Unit
Turn on the PCU and select the filter function; the air in the pump must be released. Unscrew
the Air Valve counter-clockwise and release the air until the water is coming out, then screw
the air valve clockwise tightly. Use a towel to dry off the pump.
8. Thermal Blanket
Place Thermal Blanket on water surface for
more efficient heating and improved heat
retention.
The filter cartridge should be cleaned weekly and replaced on a monthly basis, or depending on
use. A reminder will appear to change the filter after 25 days (‘CHG FIL’). Hold the filter button for 5
seconds to clear the message. Change water once a month or depending on use and use
appropriate spa chemicals. Please pay attention to the chemicals used and dosage. Spa damage
resulting from misuse of chemicals is not covered by the warranty.
Water Balance: We recommend you maintain your water balance: PH value: 7.2 - 7.6; Free
Chlorine: 2ppm - 3ppm. Use test kit to test your spa water before each use of the spa, or at least
once per week.
Water Sanitation: We suggest using chlorine or bromine granules to disinfect the spa’s water.
Never add tablets freely to spa water; a floating dispenser is recommended.
Cleaning the Spa: Clean the spa with soap and water, then rinse. Leave it outside (away from
direct sunlight) to dry.
Repairs: Small holes or punctures can be repaired with the repair kit that comes with the spa (glue
not included)
(1.) (2.) (3.)
MAINTENANCE / TROUBLE SHOOTING :
PROBLEM
Cloudy water
Odour
Eye skin/irritation
POSSIBLE CAUSE
High pH (test to verify)
Poor filtration
High dissolved solids
High level of organic contaminants
Low pH and/or alkalinity
combined Chlorine due to organic
contamination
SOLUTION
Add pH down
Clean filter w/Filter Free
Empty spa and re-fill
Increase the amount of Chlorine
Add Alkalinity Booster
Increase the amount of Chlorine
Granules
Part 4 USAGE
(Fig. A)
Press the Temperature Setting Button to set an appropriate temperature. Press the
Heating Button to heat the water. Put on the lid while heating. Once the water reaches the
desired temperature you can enjoy your spa. Press the Jet Massage Button to activate
massage system. We suggest a temperature range between 98.6°F-102°F (37-39℃)
during the winter. The massage system will stop automatically after 30 minutes of
operation to reduce energy consumption. Re-activate the Jet Massage function by
pressing the Jet Massage Button again (See Part 7 for Control Functions).
Lock the Buckle
Push the square pad upwards to lock and downwards to unlock (Fig. A).
(Fig. A) (Fig. C1) (Fig. C2)
(Fig. B)
‘O’Ring Gasket
8
11
Part 6 : DRAIN & STORE
Drain System
Locate and remove the external threaded Drain Cap. Attach Drain Hose to Drain Outlet.
Locate and remove the stopper on the spa floor to allow water to drain.
Dry the Spa and Portable Control Unit
After a GFCI test, press the Jet Massage Button to blow out the water inside the jet holes.
Unplug the PCU, remove the filter cartridge from the Filter Housing and dry the PCU by draining
all water from PCU body and pipes. Open the Drain Valve on the bottom of the PCU, let the water
flow out and close the Drain Valve.
Storage
Use a towel to wipe off the spa and dry for 24 hours. Unscrew the Air Valve on both the
spa and the lid. Once the spa and lid has been deflated and the Foam Panels have been
disassembled, gently fold them for storage. It is recommended that you store the spa in its
original package in a warm dry place.
Part 7 PORTABLE CONTROL UNIT FUNCTION
A. Temperature Increase
Button
C. Blower/Jet
massage Button
B. Temperature Decrease
Button
D. Filter Button
E. Heat Button
G. Temperature Mode Button
F. LED Display
Functions of the Spa Portable Control Unit
LED Display: Once powered-up, the LED display will show the current water
temperature automatically.
‘Temperature Adjustment’ Buttons (A & B): Increase (A) Decrease (B). Pressing one
of the temperature adjustment buttons will cause the LED display to flash. When
it is flashing, you can set the desired temperature. The value will increase or decrease
by 1°F/ 1°C for each press. If you hold the button for 2 seconds, the values will
increase/decrease rapidly.
Temperature Adjustment Ranges: 86°F - 104°F/ 30°C - 39°C To lock the Portable
Control Unit, press (A) + (B) at the same time and hold them for 3 seconds. When the
spa is left unattended please be sure to lock the PCU to avoid having
the settings changed. Unlock the PCU by pressing (A) + (B) at same time
and holding for 3 seconds again.
‘Temperature Mode’ Button (G): Press this button to change from Celsius to Fahrenheit.
‘Jet Massage’ Button (C): Press this button to activate the Jet Massage system; when
activated a green indicator light turns on and ‘BUB’ is displayed on the screen. It can be
turned off by pressing it again.
NOTE:
The massage system will stop automatically after 15 minutes of operation. Re-activate
the jet function by pressing the jet button again.
When the filter mode is on, pressing the Jet Massage Button (C) will cause the filter
mode to turn off and the jet massage mode to turn on.
Heating and jet function can not be activated at same time. When heating system
is working, pressing (C) will change heating mode into jet mode: heating and filtering
are shut down, jet system is activated. If you press (C) again, heating and filtering
mode will re-start.
Pressing Filter Button (D) activates the filter system. This button turns the filter pump on
and off. The green indicator light will turn on when the filtration system is activated.
Note: When heating and filter functions are working at same time, pressing (D) will shut
down heating and filtering together. When (C) is on, filter and heating cannot be
activated, therefore (C) should be shut down first.
Pressing the Heat Button (E) activates the heating and filtering system at the same time
The green filter light and red heat light will be activated at the same time. The PCU
does not stop heating until the current water temperature reaches the set
temperature indicated by the ‘blinking’ red light.
When you press the Blower Button (C) the circulation pump and the heater will stop, as
a consequence the temperature on the display will decrease (due to no flow of water
between the PCU and the spa). To regain heating functionality turn the Blower Button (C
off and press the Heat Button (E). The circulation pump will restart and the temperature
will increase or the heating mode will restart automatically after the water temperature
drops 1°F/ 1°C (approx) below the set temperature. Max. heat temperature: 104°F (39°C).
Allow 24-48 hours to heat up your spa.
• This spa is equipped with automatic moisture protection which will activate the blower
of the PCU once a day for 90 seconds. This helps to prevent condensation build up and
increase the lifespan of the PCU.
Heater
Port
Blower Port
Air Valve
Filter Housing
Filter Port
Digital Display Pad
The Portable Control Unit
(PCU)
10
13
CHECK 1 - Water Level
Ensure water level meets fill lines on both interior
sides of the spa. Check if this resolves the pump’s
malfunctioning.
CHECK 2 - Inside Connection Caps
Make sure the clear plastic connection caps have been
removed before turning on the pump.
CHECK 3 - Bleed Air out of Portable
Control Unit
If PCU makes a grinding noise, no water is going to the
pump. Bleed the air out of the pump by unscrewing the
Air Valve till water is released then re-tightening it. Check
if this resolves the pump’s malfunctioning.
CHECK 4 - Check Spa for Obstructions
Check that inlet/outlet ports inside the tub are clean
and remove any obstructions detected. Check if this
resolves the pump’s malfunctioning.
CHECK 5 - Check Filter Is Clean
Check the filter. If the filter is dirty or scaled wash and/or
replace it.. Check if this resolves the pump’s
malfunctioning.
CHECK 6 - Make Sure Connectors Are
Not Kinked
Check the connection hoses. Make sure that they are not
kinked or bent and that both the spa and the PCU are
set on the same level surface. If you still cannot solve this
problem, please contact us for service.
Part 9 :
SPA OPERATION CHECK LIST
CODE
Causes
Solutions
E1/ E2
Temperature control
sensor short circuit
or open circuit
1. Unplug GFCI from outlet
2. Please contact for service
E3
High Heat:
The water is
over 113F(45℃)
1. Unplug the GFCI cable from the outlet
2. See Part 9: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please contact for service
E4
Freezing Conditions Detected:
The water is lower than
36F(2℃)
1. Unplug the GFCI cable from the outlet
2. See Part 9: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please contact for service
E5
Overheat:
The water is
over 122F(50℃)
1. Unplug the GFCI cable from the outlet
2. See Part 9: Spa Operation Check List for possible solutions
3. Power on spa again to see if error is resolved, if not please contact for service
E6
Inlet or outlet on inner
wall are blocked
Filter cartridge is too
dirty
Spa water does not
reach minimum water
level
Air-lock in pump
See Part 9: Spa Operation Check List for possible solutions,
otherwise contact for service
E7 Heater Dry See Part 9: Spa Operation Check List for possible solutions,
otherwise contact for service
Reset Procedure for Portable Control Unit (if unit overheats)
Locate the small hole marked “RESET” on the bottom of the PCU and
insert a thin object (It should be less than 0.9cm) into the hole and press
down. Reconnect the PCU to the spa.
Part 8 :
PORTABLE CONTROL UNIT ERROR MESSAGES
12
Part 10 :
FREQUENT PROBLEMS SOLUTION
Problems Causes Solutions
Spa Pump
Does Not
Operate
• GFCI tripped
• GFCI broken
• Check power source
• Power failure
• Reset GFCI/check if the cable is rated 2kW / 15A
• Call for service if it does not reset
Spa Pump
Does Not
Heat Properly
Temperature set is too low
• Filter Cartridge is dirty
Water level is too low
• Heating element failed
• Set to a higher temperature
• Clean/replace the filter cartridge
• Fill water to min. water level
• Call for service
Jet Massage
System Does
Not Work
• Pump is too hot
• 30-minute auto shut off
feature is activated
• Something is wrong with
the control panel
• Unplug the GFCI cord
When the pump has cooled, reset the GFCI and press the Jet
Massage Button to activate again
• Press the Jet Massage Button to reactivate
• Call for service if it does not reset
Water Filtration
Is Not
Working
• Dirty filter cartridge
• Inlet/outlet port blocked
• Air lock
• Something is wrong with
the control panel
• Clean/replace the filter cartridge
• Clean the inlet/outlet ports
• Purge air from the pump as previously outlined
• Call for service if it does not reset
Portable Control
Unit Leaking
Adaptor seal improperly
located
Water leakage from pump
body
• Ensure Check Valve below PCU is tightened
• Check the pump body
• Call for service
Spa Leaking • Spa is torn or
punctured
• Use provided repair patch as previously
outlined
Water Is Not
Clean
• Insufficient filtering time
• Dirty filter cartridge
• Improper chemical treatment
• Do filtration longer and more frequently
• Clean/replace the filter cartridge
• Change the spa water completely
• Refer to the chemical manufacturer’s
instructions.
Red Light
Blinking
• Spa has reached set
temperature
The pump does not stop heating until the current water
temperature reaches the set temperature indicated by the
‘blinking’ red light.
ATTENTION: PLEASE KEEP ALL ORIGINAL PACKAGING IN CASE OF WARRANTY ISSUES!
If you experience any problems, please do not hesitate to contact your local dealer or our after sales
service immediately. Any defect or damage caused by installation, alteration, or repair, by anyone
who is not an employee of Canadian Spa Co., or authorized service technician, is not covered by
the Warranty. This Warranty becomes void if the spa has been subjected to misuse, abuse,
alteration, or attempted alteration, repairs or attempted repairs by anyone other than an authorized
Canadian Spa Co. service technician, improper installation, improper water chemistry, improper
maintenance, acts of god, or damage caused beyond the control of Canadian Spa Co. Misuse and
abuse shall include any operation of the spas other than as directed in the Canadian Spa Co.
Manual. Examples of misuse and abuse include, without limitation: damage of the spa liner caused
by leaving the spa uncovered while the spa is empty of water or not in use. Damage to the spa
surface caused by contact with unapproved cleaners or solvents. Damage caused by unapproved
sanitizers such as calcium hypochlorite, tri-chlor type chlorine or any sanitizing chemical that may
remain undissolved on the spa vinyl surface.
Accessories (0ptional)
3 Pack Filter (Buy 3 Get 1 Bonus)
3 x 15 ft² slip replacement filters for Canadian Spa Company portable spas.
This filter should be changed every 1-2 months (depending on usage).
Portable Chemical Kit:
This chemical kit is an excellent addition to any spa and provides users with all of the essential spa
chemicals needed to keep a spa balanced. The following chemicals are included in the kit:
Chlorinated Granules 800g • Alkalinity Booster 800g • pH Up 1kg • pH Down 1kg • Test Strips
Booster Seat:
Water filled booster seat for added comfort and great for small children.
Portable Spa Pillow:
Pillow attaches to the perimeter rim of portable spa.
Round 7’ Cover Cap:
Waterproof, tough & durable • Prevent cover colour bleaching • Resists UV damage • Elastic sewn
into 12” (30.5 cm) hemmed skirt for a snug fit • Fits most spa models and shapes • Made from
durable woven polyethylene
Hard Top Cover
Thick tapered cover for unparalleled heat retention • 5” Skirt length • Commercial quality zipper
Locking straps for added protection • Tough mesh bottom with rugged reinforced stitching
Step:
Simple to assemble, these spa steps allow for quick and easy entry into a spa while providing a
non-slip surface for safety.
• No tools required to assemble • Made of durable UV protected polypropylene
Synthetic Gazebo:
Free standing gazebo.
• 10’ x 10’ • Louvred panels • Smoked acrylic corner window • Skylight • Bar counter
Spa Surround Furniture:
All items are customizable to create your own personal spa furniture configuration.
Items Include: • Sofa • Bar Table • Side Table • Planter • Step
Sofa
Bar Table
Side Table
Planter
Step
www.canadianspacompany.com
INFORMATION:
For Product Support Visit:
support.canadianspacompany.com
North America Office:
Canadian Spa Company
2-3620B Laird Road
Mississauga, Ontario
Canada, L5L 6A9
T: +1-877-347-7727
F: +1 (905) 825 2513
www.canadianspacompany.com
UK Office:
Canadian Spa Company
Canada House
Salbrook Road
Salfords, Redhill
Surrey, RH1 5GL, UK
T: +44 1293 824094
F: +44 1293 824750
www.canadianspacompany.co.uk
German Office:
Lützerathstrasse 127
51107 Köln
T:0049-221-94655344
F:0049-221-94655342
www.canadianspacompany.com
Asia Office:
Canadian Spa Company
No.460 Lanxue Road,Huanglou,
Pudong Area Shanghai,P.R.China
Post Code 201205
Tel : +86 21 58942200
Fax: +86 21 58940305
www.canadianspacompany.com
Disclaimer: Canadian Spa Co. or any of its authorized service technicians shall not be held liable for injury, inconvenience, loss of use,
chemical or water damage, transportation costs, continent liabilities or any other incidental or consequential costs, expenses or damage
as result of any deficiency or alleged deficiency of the spa. In no event shall Canadian Spa Co. be liable, for any reason or cause, in
excess of the amount paid for the product. No other warranties, expressed or implied, are valid. No agent, dealer, distributor, service
company or other party is authorized to change, modify, or extend, the terms of this Limited Warranty in any manner whatsoever.
Do not return the product to the store.
Contact your local after sales service centre.
Errors and omissions excepted (E&OE). 03/19/16
16
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Swift Current at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Swift Current in the language / languages: English as an attachment in your email.

The manual is 7,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Swift Current

Canadian Spa Company Swift Current User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info